8
LED LIGHT REMOVAL/REPLACEMENT, PLUG/CORD POSITIONING, PROPER PLUG INSERTION
Light Switch
1. LED Style Light Fixtures
Removal of Faulty LED Lights:
Contact Structural ConceptsTechnical Service
Department for replacement LED lights.
Turn off LED light switch.
To remove faulty LED light, follow these steps:
A. Disconnect plug from LED light.
B. Using both hands, grasp LED light assembly (with its
magnetic mounting clips). Pull downward and off its
shelf (or header).
C. Remove magnetic mounting clips from LED light by
pressing against flange part of clip with thumb.
>> Note: Mounting clips MAY be riveted to shelf or header.
In such instances, simply remove LED light from mounting
clips by pressing against flange part of clips with thumb.
Replacement of LED lights:
Attach magnetic mounting clips onto LED light.
Adjust magnetic mounting clips so they are equally
spaced on LED light.
Reattach LED light assembly to its shelf/header.
Position properly in shelf/header.
>> Note: If mounting clips are riveted to shelf (or header),
attach by placing LED in base of clip and then snapping into
clip at FLANGE SIDE.
Press plugs barrel-shaped insert deep into LED light.
Important: If plug is not inserted ALL THE WAY IN the
LED lights orifice, the light may not energize. See
BAD vs. GOOD insertion illustrations below-right.
Turn LED light switch back on.
Magnetic Mounting
Clip View #2
LED
Lights
B
A
Plug
Barrel
Shaped
Insert
LED
Light
C
Magnetic Mounting
Clip View #1
No Gap
Gap
LED Lights
LED Lights
LED Lights