START-UP AND OPERATION / THERMOMETER LOCATION AND FUNCTION
1. Merchandiser Start-Up
Unit will energize when properly field wired.
Evaporator coil fans will automatically turn on.
From the front of the case, lift glass and remove
the decking; check to see that the coil fans are all
functioning properly.
Lights switch is accessible at case front-left, near
upright. See illustration below.
Turn light switch on. All lights should come on at
the same time. First time lighting may require a
short warm up-period for the bulbs.
Slightly dim or a flickering of new bulbs is normal.
If lights do not turn on, check all raceway
plugs. The lighting is wired in series so all
lights must be plugged in or receptacles
capped in order for the case to light.
See next page for illustration of scale stand
receptacles.
Digital Thermometer
2. Thermometers - Location and Function
Refrigeration section has been tested to
maintain temperature at or below 5° Celsius /
41° Fahrenheit.
Spirit-filled and/or digital thermometers are
usually found at case rear near light switch.
Thermometers are for monitoring warmest air
temperature.
Thermometers reflect internal air temperature
only (not actual food temperature).
Use probe thermometers to determine actual
product temperatures.
41°F
Light
Switch
or
Spirit-Filled
Thermometer
Note: Illustration shown may not
exactly reflect every feature or
option of your particular case.