Structural Concepts Fusion GMSS1052R handleiding

30 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 25 van 30
25
TROUBLESHOOTING - GENERAL - PAGE 2 of 2
CONDITION TROUBLESHOOTING
Case Is Not Holding
Temperature
If a large amount of warm product was added to the case, it will take time for
the temperature to adjust. Unit needs product to be pre-chilled.
Check that the discharge air grille is not disrupted or blocked by product.
Check that the case is not in the sun or near a heat or air-conditioning vent.
If case is located near front doors, temperature fluctuation can hinder units
ability to maintain temperature. See OVERVIEW / CONDITION TYPE /
COMPLIANCE / WARNINGS / PRECAUTIONS / WIRING section in this
manual for specifics.
Case Lights Are Not
Working
Check that light switch is in the on position.
LED Lights: Check plugs and lights for proper connection (illustrated below).
Check for burned out bulbs. If so, turn lights off & replace.
Trained Service Providers Only: Check to insure voltage at ballasts. If voltage
is entering but not exiting ballast, ballast is faulty.
No Gap
Gap
LED Light
Plug
LEDs Barrel
Shaped Insert

Bekijk gratis de handleiding van Structural Concepts Fusion GMSS1052R, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkStructural Concepts
ModelFusion GMSS1052R
CategorieNiet gecategoriseerd
TaalNederlands
Grootte12689 MB