PREVENTIVE MAINTENANCE (TO BE PERFORMED BY TRAINED SERVICE PROVIDER) - Page 2 of 2
PREVENTIVE
MAINTENANCE
FREQUENCY INSTRUCTIONS
Case Exterior Quarterly Compressor Area: Warning! Disconnect power from the case before
cleaning Condenser Coil!
Slide/Roll out from under case.
Use moist cloth to wipe off dust & debris that collects on various
parts.
Quarterly Condensate Pan: Disconnect from receptacle box. Remove mounting
screws from base. Use a de-scaling solution (such as CLR® that will
prevent corrosion, lime and rust) to clean pan. Rinse thoroughly; do
not submerse in water.
Quarterly Under Case Cleaning: Once refrigeration package is clear of unit,
vacuum under case to remove all dust and dirt that may collect under
case.
Case Interior Quarterly Tub, Coil and Drain: Remove Evaporator Fan Panel and clean Tub,
Coil and Drain with warm water and mild soap solution. Remove any
debris that may clog drain.
Quarterly Fan Blades, Motor, and Bracket: Wipe down each blade, motor and
bracket with moist cloth.
Quarterly Honeycomb: Remove the honeycomb. Vacuum, then clean with
warm water and soap. See specific instructions in the Maintenance
Fundamentals section of this manual.