INSTALLATION: REFRIG. LINE & DRAIN STUB-UP CONNECTION - MODEL GJDSS6RLB ONLY
7. Refrigeration Line Stub-Up Connection
Remove front panel/toe-kick. Refrigerant stub-up
access opening is at the front on the left hand
side of the base (as shown in illustration below).
See next page for Model GJDSS8RLB
refrigeration line stub-up connection layout.
8. Evaporator Coil Drain Connection
Coupler connection point is under the case on the
right hand side (as shown in below illustration).
Front panel/toe-kick may be removed to allow
access when connecting PVC drain tube to
coupler.
Maintain 1/4”-fall per foot to provide proper
drainage.
See next page for Model GJDSS8RLB evaporator
coil drain connection layout.
--- Case Rear ---
--- Case Front ---
Refrigeration
Lines Stub-Ups
Coupler
Note: Model GJDSS6RLB is Shown Above.
See Next Page for Model GJDSS8RLB Layout
Wire Raceway
Hat Channel
Wire Raceway
Note: Illustration Above May Not Reflect Every
Feature or Option of Your Particular Case
PVC Drain Tube (To Be
Attached To Coupler)