INSTALLATION, CONTD: DISPLAY CASE START-UP (CASE / LIGHTS / TEMP. CONTROLLER / SST)
Cap
Plug
Receptacle
Raceway Receptacle, Plug and Cap
Raceway
20. Display Case Start-Up
A. Case
Remote: Case will power-up when properly field
wired (or plugged in).
Self-contained: Turn main power on.
After case is powered up, lift curved or flat front
glass by grasping lift handle and raising (see
illustration at right).
Note: Illustration at right reflects flat front glass.
Yours may have curved front glass.
Lift deck to check that coil fans are running.
Coil fans (and in self-contained units, compressor
motor) should turn on.
B. Lights
Turn lights on.
> Switch is either at case front, attached to rear
plenum, above top shelf (as shown at right) or at case
rear (as shown at top-right).
> In cases with NO SWITCH, lights will come on
when case powers up.
All lights should come on at the same time. If
bulbs are fluorescent, first time lighting may
require a short warm-up period. LEDs have no
warm-up period.
Slightly dim / flickering of new bulbs is normal.
If lights do not turn on, check raceway plugs.
Lighting is wired in series so all lights must be
plugged in or receptacles capped for case
lights to be on. See illustration at right.
LED Lights: If lights do not come on, check that
plug is properly inserted into socket.
C. Temperature Controller (All Self-Contained
Units and some Remote Units)
Check that compressor symbol light is on.
After case has run for a few minutes, check that
temperature starts to drop.
If temperature controller does not begin cooling
(in a few minutes) see temperature controller
section in this operating manual for instructions.
Remote units (without temperature controller on
case): Verify that refrigeration requirements listed
on serial label (found on the case) are being met.
D. Saturated Suction Temperature (Remote)
See serial label on case for suction temperature
requirements and BTU requirements.
See serial label on case for defrost schedule and
temperature termination parameters.
Main Power
Switch
Light Switch (On
Certain Self-
Contained Units)
Temperature
Controller
Coil Fans
Raceway
Plugs (See
Illustration
Below)
Light Switch at Rear
Plenum Above Top Shelf
(On Remote Units and
Various Self-Contained
Units)
Self-Contained Unit Control Panel
(With Temperature Controller)