CASE OPERATION: MAIN POWER / LIGHTS / THERMOSTATS / OPERATING TIPS / SHUTDOWN
1. Start-Up - Note: This Section Is For
Authorized Personnel Only!
• Control panel is at case rear. It may be
accessed by removing rear panel (no screw
removal required).
• Main power switch, lights switch and thermostats
are on control panel. Replace front panel after
energizing control panel
• Turn main power switch on to energize case
(heated deck, heated shelves and lights).
• Turn on light switch for case lights to come on.
• Caution! Deck, shelving and overhead lights are
HOT! Do not touch until case has been turned off
and allowed to cool for 45 minutes!
2. Pre-Cooking Food / Checking Food Temp.
• Caution! Food MUST BE cooked PRIOR to
being placed in the case. Food should be heated
to between 150 °F to 160 °F (65.6 °C - 71 °C)
prior to placing it in the case.
• Temperatures of all food products are to be at
140 °F to 165 °F (60 °C to 74 °C), for shelves
and deck.
• Food temperature must NOT be allowed to be
below FDA guidelines of 140 °F (60 °C).
• Use ONLY food probe to check product
temperature before placing it in case.
DECK
• DO NOT rely on case thermometer or
infrared thermometer gun!
• After product is placed in case, check product
temperature (again) after one hour to verify that
proper food temperatures are maintained.
3. Thermostat Settings
• Important! Default thermostat settings are set
at the factory. This case should rarely require
adjustments to thermostat settings.
• If thermostat settings need to be adjusted, see
Programmable Controller section in user manual.
• If temperature is adjusted, allow 20 minutes at
NEW settings to determine if product
temperatures are acceptable.
• Check food temperature again after one hour.
4. Operating Tips
• When restocking, place new product at back and
rotate older product to front of case.
• Display product expected to sell within 4 hours.
• Clean up residue immediately. Spills will harden to
surface very quickly!
5. Shutting Down Case
• Remove all product from case.
• Turn main power switch to “OFF” position.
• Allow case to cool for 45 minutes before cleaning.
• See Cleaning Schedule section in User Manual