CONDITION TROUBLESHOOTING
Weight Sensors On
Shelf/Shelves Are
Malfunctioning
Contact Instant Retail Systems (see last page of User Manual).
Color-Coded Lights
On Shelf/Shelves
Are Malfunctioning
Contact Instant Retail Systems (see last page of User Manual).
Screen/Monitor Is
Malfunctioning
Contact Instant Retail Systems (see last page of User Manual).
Payment Processor
Is Malfunctioning
Contact Instant Retail Systems (see last page of User Manual).
Case Is Not Holding
Temperature
You must load case with pre-chilled product. A warm load can result in air
temperature of food storage compartment exceeding 45 °F (7 °C) for more than
15 minutes; this can result in vending mechanism disablement.
Temperature changes during defrost mode but will return to normal.
Check that case is not directly in the sun.
Check that condenser coil has been cleaned.
Check air return opening for obstructions.
If sight glass is part of condensing unit, check if it is flashing or showing low
charge.
Check set point temperature; it may be adjusted too high.
Condensing Unit Is
Not Operating
Check that the power is turned on.
Check if programmable controller settings are properly set. See your case’s serial
label for your model’s specified settings. See SERIAL LABEL LOCATION &
INFORMATION LISTED / TECH INFO & SERVICE section in manual for label
location, etc.