Installation
(qualified
contractors)
The
installation
site
must
fulfil
the
following
requirements:
-
Free
from
the
risk
of
frost
-
Sufficient
load
bearing
capacity
(for
weight
of
the
appliance,
see
chapter
Data
table
33]}
A
plasterboard
or
metal
framed
wall
is
inadequate.
Additional
measures
such
as
a
double
skin
or
additional
supports
are
needed
in
such
cases.
The
installation
room
must
have
an adequate
condensate
drain
with
siphon.
The
type
and
location
of
the
outside
air
intake
must
ensure
that
the
least
polluted
outdoor
air
in
the
area
of
the
building
and
surroundings
is
drawn
in.
The
outside
air
intake
for
controlled
mechanical
ventilation
must
be
at
least
the
following height
above
ground
level:
700
mm.
In
addition,
you
must
observe
the
minimum
suction
height
from
the
standard
applicable
to
you.
Avoid
outdoor
air
intake
in
locations
with
polluted
air:
-
car
parks
and
roads
-
under
bushes
and
trees
-
in
the
proximity
of
waste
containers
-
locations
contaminated
with
microorganisms,
dust
or
ash
6.2
Mounting
the
appliance
Unpacking
the
appliance
Remove
the
packaging.
Put
the
accessories
supplied
aside
for
use
later.
To
position
the
appliance
on
its
underside,
carefully
tilt
the
appliance
forwards
over
the
lower
edge
at
the
back.
Fitting
the
wall
mounting
bracket
Hold
the
wall
mounting
bracket
supplied
at
the
required
in¬
stallation
location
as
an
installation
template.
The
text
"TOP"
must
be
at
the
top.
Maintain
the
minimum
clearances
in
order
to
ensure
trouble-free
operation
of
the
appliance
and
to
allow
enough
space
for
maintenance
work.
NOTICE:
If
the
appliance
is
not
mounted
horizontally,
con¬
densate cannot
drain
properly.
Condensate
escaping
in
an
=
uncontrolled
manner
can
damage
the
floor
or
items
in
the
vicinity
of
the
appliance.
For
reasons
of
hygiene,
no
con¬
densate
must
remain
in
the
appliance.
Mark
the
drilling
locations
on
the
wall
with
a
pencil
through
the
slots
and
holes
on
the
wall
mounting
bracket.
Drill
the
holes.
Secure
the
wall
mounting
bracket
with
suitable
fixing
ma¬
terials
(screws,
rawl
plugs).
Use
the
slots
to
compensate
for
any
inaccuracies
in
the
drill
holes.
Align
the
wall
mounting
bracket
horizontally.
If
necessary,
screw
the
star
grips
included
in
the
standard
delivery
into
the
back
of
the
appliance
at
the
bottom
to
act
as
spacers.
Fit
the
appliance
onto
the
hooks
of
the
wall
mounting
bracket.
If
the
appliance
is
not
horizontal,
screw
the
star
grips
in
or
out by
a
small
amount.
6.3
Connecting
the
condensate
hose
NOTICE
©
Property
damage
Condensate
escaping
in
an
uncontrolled
manner
can
damage
the
floor
or
items
in
the
vicinity
of
the
unit.
Do
not
kink
or
twist
the
condensate
hose
during
fitting.
Arrange
the
condensate
hose
with
a
minimum
fall
of
10
%.
The
condensate
hose
may
contain
only
one
siphon.
The
con¬
densate
must
be
able
to
drain
freely
downstream
of
the
siphon.
Drain
the
condensate
into
the
domestic
sewer
system.
The
pipes
of
the
domestic
sewer
system
must
not
rise
down¬
stream
of
the
siphon.
The
condensate
drain
must
be
free
from
the
risk
of
frost.
A
float
switch
prevents
condensate
from
reaching
live
parts
in
the
unit.
If
the
condensate
hose
is
installed
incorrectly,
the
float
switch
cannot
prevent
the
uncontrolled
leakage
of
condensate.
To
ensure
the
unit
is
airtight,
there
may
be
no
interruption
in
the
condensate
drain
between
the
unit
and
the
trap.
Use
the
condensate
hose
and
mounting
bend
supplied
as
standard
de¬
livery.
The
condensate
hose
must
be
connected
to
the
"Condensate
drain"
(d45)
connection
on
the
exhaust
air
side
of
the
appliance.
Position
of
the
condensate
hose
Right-hand
version
(delivered
right
condition)
_
Left-hand
version
left
Remove
the
condensate
seal
from
connection
"Condensate
drain".
There
is
a
thermal
insulation
part
in
the
recess
surrounding
the
"Condensate
drain"
connection.
www.stiebel-eltron.com
VRC-W
450/600
Premium
|
7

Bekijk gratis de handleiding van Stiebel Eltron VRC-W 600 E Premium, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkStiebel Eltron
ModelVRC-W 600 E Premium
CategorieNiet gecategoriseerd
TaalNederlands
Grootte143775 MB