Installation
(qualified
contractors)
6.7.1
Insulation
against
condensation
NOTICE
©
Property
damage
When
warm
air
meets
cold
surfaces,
condensation
can
result.
For
outdoor
air
and
exhaust
air
ducts,
use
vapour
proof
thermally
insulated
pipes.
In
unheated
rooms,
insulate
the
supply
and
ex¬
tract
air
ducts.
6.7.2
Connecting
air
ducts
to
the
appliance
Make
an
airtight
connection
between
the
air
duct
and
the
appliance,
e.g.
with
a
twin
nipple.
6.7.3
Sound
reduction
To
prevent
structure-borne
sound
transmission,
ensure
a
flexible
connection
between
the
appliance
and
the
air
duct.
To
minimise
noise
from
the
appliance,
fit
silencers
to
the
supply
air
and
extract
air
ducting
in
the
immediate
vicinity
of
the
appliance.
To
prevent
sound
transmission
in
the
air
ducting,
fit
inline
silencers
at
appropriate
points
in
a
sequential
distribution
system
or,
in
a
star
distribution
system,
on
individual
spokes
of
sufficient
length.
To
keep
the
noise
level
low,
design
the
system
to
keep
the
air
flow
rate
per
fan as
low
as
possible.
If
necessary,
install
several
fans
each
with
their
own
inlet
ducts.
6.7.4
Overflow
apertures
Living
rooms
and
bedrooms
are
only
supplied
with
air.
Air
is
only
extracted
from
rooms
where
odours
and
moisture
are
gen¬
erated.
Ensure
an
unimpeded
overflow
and
consequently
air
balancing.
Fit
ventilation
grilles
in
internal
doors
or
walls,
or
increase
the
air
gap
below
the
door
to
> 8
mm
to
ensure
an
unim¬
peded
air
flow.
6.7.5
Cleaning
apertures
Fit
cleaning
apertures
when
installing
the
air
ducts,
so
that
the
air
ducts
can
be
inspected
and
cleaned
at
regular
inter¬
vals.
Cleaning
apertures
such
as
those
on
air
distributors
must
be
ac¬
cessible
for
regular
cleaning.
6.7.6
External
wall
outlets
Position
the
air
intakes
on
the
building
such
that
the
air
drawn
in
is
not heavily
polluted.
Avoid
drawing
in
dust,
soot,
odours,
flue
or
exhaust
gases,
microorganisms
and
ash.
Prevent
short
circuits
between
exhaust
air
and
outdoor
air.
Position
the
external
wall
outlets
and
intakes
around
a
corner
from
one
another.
If
the
outdoor
air
intake
and
the
exhaust
air
outlet
are
on
the
same
side
of
the
building,
there
must
be
a
minimum
of
2
m
between
them.
If
this
is
impossible,
create
a
separation
between
the
air
streams,
e.g.
by
means
of a
separating
wall
or
shrubs
between
the
outdoor
air
intake
and
exhaust
air
outlet.
Never
install
the
apertures
facing
towards
neighbouring
liv¬
ing
room
or
bedroom
windows.
6.7.7
Supply
and
extract
air
vents
For
living
space,
supply
and
extract
air
vents
are
provided
for
installation
in
a
wall
or
ceiling.
In
kitchens,
install
the
extract
air
vents
as
far
as possible
from
the
cooker
hob.
Supply
air
and
extract
air
vents
must
be
installed
and
set
up
in
accordance
with
the
manufacturer's
instructions.
6.8
Electrical
connection
NOTICE
©
Overvoltage
Overvoltage
can
cause
damage
to
the
appliance,
and
may
destroy
it.
Ensure
that
the
voltage
specified
on
the
type
plate
conforms
with
the
mains
power
supply.
6.8.1
Connections
in
the
control
panel
When
routing
the
power
cable,
ensure
a
watertight
fit
where
it
passes
through
the
cable
grommet.
The
control
panel cover
is
on
the
upper
side
of
the
appliance.
Undo
the
screws
of
the
control
panel
cover.
Carefully
lift
up
the
control
panel
cover.
Drill
or
break
open
one
of
the
pre-marked
apertures
on
the
control
panel
cover.
Slide
a
threaded
cable
gland
over
the
cable
to
provide
a
seal.
Fix
the
cable
gland
to
the
control
panel
cover.
Connect
the
cable
in
accordance
with
the
wiring
diagram.
See
chapter
Wiring
diagram
[>
30],
0-10
V
input
You
can
control
the
appliance
via
this
input.
See
parameter
"0-10
V
input"
in
chapter
'
Settings"
menu
[>
22],
X20.3
_
GND
_
X20.4
_
HO
V
_
Intensive
ventilation
switching
contact
You
can
connect
a
floating
switching
contact,
the
actuation
of
which
switches
the
appliance
to
intensive
ventilation.
You
can
set
the
runtime
for
intensive
ventilation
in
parameter
"Intens,
vent.
time".
After
this
time
has
expired, the
unit
switches
back
to
its
previous
state.
Connect
the external
pushbutton
to
the
terminals.
X19.1
_
GND
_
X19.2
_
+5V
_
External
programming
unit
1/2,
external
heating
coil,
connectivity
X121
_
SPA
_
X122
_
+5V
_
X123
_
GND
_
X124
SCL
www.stiebel-eltron.com
VRC-W
450/600
Premium
|
15