Transportation
(qualified
contractors)
Operating
mode
Fan
set¬
ting
Description
Reduced
1
Reduced
ventilation
is
the
ventilation
ventilation
necessary
to
meet
hygiene
standards
and
ensure
protection
of
the
building
structure
(moisture
level)
under
nor¬
mal
conditions
of
use
with
partially
reduced
moisture
and
pollutant
loads,
e.g.
due
to
temporary
absence
of
the
user.
Standard
2
Standard
ventilation
is
the
ventilation
ventilation
necessary
to
meet
hygiene
standards
and
ensure
protection
of
the
building
structure
when
users
are
present.
Intensive
3
Intensive
ventilation
is
ventilation
at
a
ventilation
higher
flow
rate
to
reduce
load
peaks,
e.g.
for
rapid
ventilation
dur¬
ing
or
after
a
party.
You
can
switch
on
intensive
ventilation
with
the
pro¬
gramming
unit
or
with
an
optionally
connectible
external
pushbutton.
Time
pro-
0
-
2
Time
controlled
fan
program
with
gram
mode
separately adjustable
fan
settings
Flow
rate
control
The
qualified
contractor
sets
the
air
flow
rate
for
each
fan
set¬
ting
during
commissioning.
Constant
flow
rate
control
ensures
that
the
air
flow
rates
through
the
supply
air
and
extract
air
fans
are
achieved
irrespective
of
the
duct
pressure.
4.3.1
Frost protection
The
appliance
has
a
frost
protection
controller,
which
ensures
that
it
works
to
optimum
effect
even
at
low
outside
temperat¬
ures.
If
the
outdoor
air
temperature
falls
below
the
selected
frost
protection
value,
the
integral
electric
preheating
coil
is
switched
on.
This
prevents
the
cross-countercurrent
heat
ex¬
changer
from
freezing
up.
The
integral
electric
preheating
coil
is
referred
to
in
these
instructions
simply
as the
"preheating
coil".
When
the
preheating
coil
is
active,
the
"Frost
protection”
symbol
appears
on
the
display.
Once
the
output
limit
of
the
preheating
coil
is
reached,
the
ap¬
pliance
reduces
the
air
flow
rate.
This
means
that
at
low
outside
temperatures
and
high
flow
rates,
the
appliance
may
reduce
the
air
flow
rate.
The
frost
protection
function
protects
the
appliance
from
frost,
not
the
building.
4.3.2
Bypass
mode
The
appliance
has
an
integral
bypass
damper.
The
bypass
damper
enables
filtered
fresh
air to
be
supplied
without
passing
through
the
cross-countercurrent
heat
exchanger.
Utilising
cool
outdoor
air
Cool,
fresh
air
is
required
on
summer
nights
in
particular.
In
such
cases,
in
automatic
mode,
as
much
of
the
warm
air
in
the
home
as possible
is
displaced
by
cooler
fresh
air.
This
function
is
also
referred
to
as
passive
cooling.
Utilising
warm
outdoor
air
In
spring
and
autumn,
the
appliance
can
increase
the
room
temperature
by
opening
the
bypass
damper
in
automatic
mode
and
drawing
warmer
outdoor
air
into
the
building.
4.3.3
Right-hand/left-hand
versions
The
appliance
offers
the
option
of
switching
the
(extract
air/sup-
ply
air)
ducts
on
the
living
space
side,
with
the
(exhaust
air/out-
door
air)
ducts
on
the
outdoor
air
side
from
right
to
left.
Positions
of
connections
"Outdoor
air"
(g03)
and
"Exhaust
air"
(g04)
on
the
cover
Right-hand
version
right
(delivered
condition)
_
Left-hand
version
_
left
_
kA
WLAN
The
appliance
has
an
integral
WLAN
module.
4.4.1
App
Using
the
app
you
can
pair
the
WLAN
module
with
your
mobile
device.
The
app
is
available
for
iOS®
and
Android®.
-
MyStiebel
Once
pairing
is
completed,
you can
use
the
app
to
control
a
number
of
functions
that
would
normally
be
controlled
with
the
ventilation
appliance's
programming
unit.
4.4.2
Conditions
Router
requirements
-
Supported
encryption:
-
WPA™
PSK
-
WPA2™
PSK
-
WPA3™
PSK
-
Port
443
must
be
open
Mobile
device
requirements
-
Check
in
the
Apple
App
Store®
or
Google
Play
Store™
that
your
mobile
device
meets
the
requirements
specified
for
the
app.
General
requirements
-
You
accept
the
app's
conditions
of
use.
-
Internet
access
is
available
-
Company
networks
are
not
supported.
-
Do
not
pair
the
WLAN
module
with
unsecured
or
public
net¬
works.
-
Do
not
use
WLAN
guest
access
for
the
pairing.
Some
WLAN
networks
with
guest
access
do
not
allow
the
pairing
of
WLAN
modules
with
mobile
devices.
5
Transportation
(qualified
contract¬
ors)
-
The
appliance
casing
is
not
designed
to
withstand
strong
forces.
►
Protect
the
appliance
against
heavy impact
during
trans¬
port.
►
If
the
appliance
is
transported
without packing
and
without
using
a
pallet,
take
care
not
to
damage
its
outer
casing.
►
Use
the
recessed
grips
on
the
underside
of
the
appliance.
6
Installation
(qualified
contractors)
6.1
Installation
site
The
discharged
cold
air
can
cause
condensation
to
be
formed
in
the
vicinity
of
the
air
discharge.
►
At
low
temperatures,
ensure
that
there
is
no
risk
of
slipping
due
to
wet
conditions
or
ice
formation
on
adjacent
footpaths
and
driveways.
6
I
VRC-W
450/600
Premium
www.stiebeL-eLtron.com