Stiebel Eltron VRC-W 450 E Premium handleiding

308 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 5 van 308
Appliance
description
3.5.1
Planning
safety
measures
Together
with
the
relevant
authorities,
engineers
plan
the
safety
measures
that
are
required
for
simultaneous
operation
of a
ventilation
unit
and
combustion
equipment.
Alternate
operation
Alternate
operation
means
that,
when
the
combustion
equip¬
ment
is
commissioned,
the
mechanical
ventilation
system
is
switched
off
and/or
cannot
be
started.
Alternate
operation
must
be
ensured
by
appropriate
measures,
e.g.
automatically
en¬
forced
shutdown
of
the
ventilation
unit.
Simultaneous
operation
Do
not
use
differential
pressure switches
in
which
the
pressure
differential
between
the
outdoor
air
pressure
and
the
pressure
in
the
combustion
equipment
installation
room
serves
as
a
re¬
sponse
criterion.
A
fault
can
arise
from
excessively
frequent
switching.
For
simultaneous
operation
of
combustion
equipment
and
a
mechanical
ventilation
system,
we
recommend
choosing
ap¬
proved
room
sealed
combustion
equipment
(in
Germany,
with
DI
Bt
approval).
If
open
flue
combustion
equipment
is
operated
in
the
dwelling
at
the
same
time
as
a
ventilation
unit,
combustion
exhaust
gases
must
be
prevented
from
penetrating
the
home
as
a
result
of
possible
negative
pressure
in
the
room.
The
ventilation
unit
may
only
be
operated
in
combination
with
intrinsically
safe
combustion
equipment.
This
combustion
equipment
has,
for
example,
a
draught
hood
or
an
exhaust
gas
monitor
and
is
approved
for
operation
in
conjunction
with
vent¬
ilation
units.
Alternatively,
external,
tested safety
equipment
can
be
connec¬
ted
to
monitor
the
operation
of
the
combustion
equipment.
For
example,
you can
install
differential
pressure
monitoring
to
monitor
the
chimney
draught
and
to
switch
off
the
ventilation
unit
in
the
event
of a
fault.
The
equipment
for
differential
pressure
monitoring
must
fulfil
the
following
requirements:
-
Monitoring
of
the
differential
pressure
between
the
connec¬
tion
piece
to
the
chimney
and
the
room
where
the
combus¬
tion
equipment
is
installed.
-
Possibility
of
matching
the
shutdown
value
for
the
differen¬
tial
pressure
to
the
minimum
draught
requirement
for
the
combustion
equipment
-
Floating
contact
to
switch
off
the
ventilation
function
-
Option
to
connect
a
temperature
capturing
device
to
ensure
that
differential
pressure
monitoring
is
enabled
only
when
the
combustion
equipment
is
in
operation,
and
that
un¬
wanted
shutdowns
due
to
environmental
influences
are
prevented
3.5.2
Commissioning
in
buildings
with
combustion
equipment
When
commissioning
the
ventilation
unit,
it
is
important
to
check
and
document
in
the
commissioning
log
that
combustion
exhaust
gases
are
not
penetrating
the
dwelling
in
a
quantity
that
is
harmful
to
health.
Commissioning
in
Germany
Acceptance
is
carried
out by
the
local
flue
gas
inspector.
Commissioning
outside
Germany
Acceptance
must
be
carried
out
by
a
specialist.
In
case
of
doubt,
you
must
involve
an
independent
expert
in
the
acceptance
pro¬
cedure.
3.5.3
Maintenance
of
the
combustion
equipment
Regular
maintenance
of
the
combustion
equipment
is
obligat¬
ory.
Maintenance
includes
checking
the
exhaust
gas
extraction
system,
the
free
pipe
cross-sections
and
the
safety
equipment.
The
qualified
contractor
responsible
must
verify
that
there
is
a
c
sufficient
flow
of
combustion
air.
41
3.6
EU
Declaration
of
Conformity
STIEBEL
ELTRON
GmbH
&
Co.
KG
hereby
declares
that
the
radio
equipment
type
VRC-W
450/600
complies
with
Directive
2014/53/
ED.
The
full
text
of
the
ED
Declaration
of
Conformity
can
be
found
at
the
following
internet
address:
www.stiebel-eltron.de
4
Appliance
description
4.1
Standard
delivery
-
IX
wall
mounting
bracket
-
2x
star
grips
used
as
spacers
-
lx
condensate
hose
-
lx
hose
clip
-
lx
mounting
bend
-
lx
"Air
connection
for
left-hand
version"
sticker
-
lx
wall
mounted
enclosure
(for
fitting
the
internal
pro¬
gramming
unit
to
the
wall)
-
lx
blank cover
(to
seal
the
upper
front
panel
when
the
pro¬
gramming
unit
is
fitted
to
the
wall)
4.2
Accessories
You
can
obtain
ventilation
pipes,
extract
air
and
supply
air
vents
and
similar
accessories
from
us.
4.2.1
Optional
accessories
-
Programming
unit
(with
wall
mounted
enclosure)
FEB
2.1
-
LWZ-W
600
Leitung
Unterdr.Sicherheitsab.:
Adaptor
cable
for
negative
pressure
safety
cut-off
switch
VRC-W
450
Premium,
VRC-W
600
Premium
-
Enthalpy
heat
exchanger
LWTF
W450/600
4.2.2
Maintenance
accessories
-
Replacement
filter
set
(see
chapter
Filter
ƒ>
26]}
4.3
Function
description
The
appliance
draws
in
outdoor
air
with
a
fan.
A
second
fan
withdraws
extract
air
from
rooms
that
are
subject
to
odours
or
moisture,
e.g.
kitchen,
bathroom,
WC.
The
extract
air
and
out¬
door
air
are routed
through
separate
air
ducts.
The
extract
air
and
outdoor
air
are
each
passed
through
a
filter.
The
extract
air
and
outdoor
air
flow
through
a
cross-countercur¬
rent
heat
exchanger.
Heat
is
recovered
from
the
extract
air
and
transferred
to
the
outdoor
air.
This
enables
a
large
proportion
of
thermal
energy
to
be
recovered.
Operating
mode
Fan
set¬
ting
Description
Humidity
pro-
0
Necessary
ventilation
to
ensure
that
tection
the
building
structure
is
protected
under
normal
conditions
of
use
with
somewhat
reduced
moisture
loads,
e.g.
during
temporary
absence
of
the
user
and
no
drying
of
washing
in
the
residential
unit
www.stiebeL-eLtron.com
VRC-W
450/600
Premium
|
5