Maintenance
14
Maintenance
WARNING
Electrocution
If
you
put
your
hand,
a
tool
or
any
object
into
the
ap¬
pliance
while
the
power
supply
is
connected,
you
may
suffer
an
electric
shock.
►
Pull
the
mains
plug
out
of
the
socket.
Component
Activity
Frequency
[months]
Filter
Check
Depending on
the
_
set
air
flow
rate
Replace
12
Condensate
drain
Check
6
We
recommend
checking
the
condensate
drain
before
the
onset
of
winter.
14.1
Filter
Product
name
Part
number
Air
type
Filter
class
[EN
779]
Filter
class
[ISO
16890]
FMS
EPMC
206610
Extract
air
GA
ISO
Coarse
65-10
65
%
W450/600
FMK
EPM1
206596
Outdoor
F7
ISO
ePMl
70-2
W450/600
air
55
%
FMK
EPA
12-2
206597
Outdoor
E12
ISO
30E
W450/600
air
99.9
%
Product
name
Part
number
Air
type
Filter
class
I
1822-1
’EN
Filter
class
[ISO
29463]
If
you
operate
the
appliance
without
filters,
it
will
become
dirty.
This
will
result
in
loss
of
hygiene,
extra
work
in
cleaning,
more
noise
and
reduced
efficiency.
Never
operate
the
unit
without
fil¬
ters.
Operate
the
appliance
with
at
least
the
recommended
filter
class.
Ensure
that
filters
are
fitted
accurately
so
they
can
func¬
tion
properly.
►
Check
the
filters
for
the
first
time
three
months
after
com¬
missioning
the
appliance.
When
the
total
fan
runtimes
reach
the
"Filter
change
interval"
parameter
set
by
a
qualified
contractor,
the
programming
unit
displays the
filter
change
symbol.
The
qualified
contractor
can
lengthen
or
shorten
the
interval
for
checking
filters
depending
on
the
level
of
contamination.
If
the
qualified
contractor
has
set
the
option
"Volume
criterion"
in
the
parameter
"Filter
detection
mode",
the
filter
change
sym¬
bol
appears
once
the
value
set
in
parameter
Filter
change
volume
has
been
reached.
►
Change
the
filters
when
the
filter
change
warning
signal
appears.
►
Pull
the
mains
plug
out
of
the
socket.
►
To
release
the
filter
cover,
press
the
cover
fastening
on
both
sides
of
the
appliance.
►
Pull
the
filter
cover
forwards
to
remove
it
from
the
appli¬
ance.
►
Undo
the
wingnuts on
the
filter
cover
by
turning
them
through
90°.
►
Push
the
filter
cover
upwards
slightly
and
pull
it
forwards
to
remove
it
from
the
appliance.
►
Grasp
the
tabs
on
the
front
of
the
filters
and
remove
the
fil¬
ters
from
the
appliance.
►
Change
the
filters
if
the
surface
is
covered
completely
in
dirt
or
the
filter
is
discoloured
throughout.
►
Change
the
filters
at
least
every
12
months.
►
Ensure
that
the
filters
are
installed
in
the
intended
position.
Air
flows
through
the
filters
from
top
to
bottom.
►
Slide
the
filters
into
the
appliance.
►
Secure
the
filter
cover
on
the
appliance
using
the
two
knurled screws.
►
Carefully
push
the
filter
fascia
onto
the
appliance.
►
Plug
the
mains
plug
into
a
standard
socket.
►
After
changing
the
filters,
set
the
"Filter
reset"
parameter
to
"On".
■=>
The
appliance
resets
the
filter
runtime
to
0.
The
para¬
meter
"Filter
reset”
is
automatically
reset
to
"Off".
The
filter
change
warning
signal
goes
out.
►
Make
a
note
of
the
filter
change
date.
►
Order
new
filters
in
good
time.
►
If
other
filters
are
installed
in
the
system,
e.g.
filters
in
the
extract
air
vents
or
a
filter
box,
check
these
and
change
the
filters
if
necessary.
14.2
Checking
the
condensate
drain
The
appliance
will
only
function
correctly
if
the
condensate
drain
is
working
and
is
filled.
If
there
is
insufficient
water
in
the
condensate
hose,
the
appliance
may
draw
in
air
through
the
hose.
►
Open
the
hose
clip
fixing
the
condensate
hose
to
the
appli¬
ance.
►
Pull
the
condensate
hose
out
of
the
appliance.
►
Check
whether
the
condensate
hose
is
soiled
by
pouring
water
through
it.
►
Clean
or
replace
the
condensate
hose.
►
Fill
the trap
in
the
condensate
hose
with
water
before
you
fit
the
hose
to
the
appliance.
15
Troubleshooting
If
the
appliance
registers
a
fault,
this
is
clearly
displayed
with
a
message.
If
more
than
one
fault
occurs,
it
is
always
the
most
re¬
cently
occurring
fault
that
is
displayed.
In
the
menu
item
"Diagnostics"
/
"Notification
list",
you
can
dis¬
play
a
list
of
the
faults
most
recently
registered
by
the
device.
►
If
you
cannot
remedy
the
fault,
contact
your
qualified
con¬
tractor.
►
To
facilitate
and
speed
up
your
enquiry,
please
provide
the
qualified
contractor
with
the
number
from
the
type
plate.
Connection
errors
Fault
Possible
cause
The
ventilation
unit
cannot
be
controlled
via
WLAN.
Pairing
was
not
completed.
There
is
no
WLAN
connection.
Remedy
Check
whether
the
WLAN
symbol
is
dis¬
played
on
the
ventil¬
ation
unit's
pro¬
gramming
unit.
26
I
VRC-W
450/600
Premium
www.stiebel-eltron.com
Bekijk gratis de handleiding van Stiebel Eltron VRC-W 450 E Premium, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Stiebel Eltron |
| Model | VRC-W 450 E Premium |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 143775 MB |