Settings
(qualified
contractors)
Heat
recovery
bypass
Set
room
temperature
Use
this
parameter
to
specify
the
outside
temperature
above
which
the
outdoor
air
bypasses
the
cross-countercurrent
heat
exchanger
by
being
routed
through
the
bypass
damper
and
dir¬
ectly
into
the
building.
Select
the
preferred
set
room
temperature
using
the
Touch-
Wheel.
Press
"OK".
Operating
mode
heat
recovery
bypass
Option
Effect
Disabled
Bypass
mode
is
permanently
disabled.
Air
flows
through
the
cross-countercurrent
heat
exchanger.
Bypass/window
Bypass
mode
is
active.
The
air
flow
by¬
contact
passes
the
cross-countercurrent
heat
ex¬
changer.
The
"Bypass
mode"
symbol
appears
on
the
display.
Outdoor
air
routing
Bypass
mode
operates
with
summer
day
automatic
detection.
This
option
is
set
in
the
de¬
livered
condition.
The
"Bypass
mode"
symbol
appears
on
the
display.
□□□■
Outdoor
air
routing
automatic:
Bypass
mode
with
summer
day
detection
For
bypass
mode
to
be
enabled,
one
of
the
following
conditions
must
be
met
for
60
minutes:
-
Set
room
temperature
+
Hysteresis
for
heat
recovery
bypass
<
Outdoor
air
temp.
-
Set
room
temperature
-
Hysteresis
for
heat
recovery
bypass
>
Outdoor
air
temp.
If
all
the
following
conditions
are
met,
the
appliance
switches
to
bypass
mode.
-
Extract
air
temp.
-
Hysteresis
for
heat
recovery
bypass
>
Outdoor
air
temp.
-
Extract
air
temp.
>
Set
room
temperature
If
one
of
the
following
conditions
is
met,
the
appliance
termin¬
ates
bypass
mode.
-
Outdoor
air
temp.
<
8
°C
-
Extract
air
temp.
-
Hysteresis
for
heat
recovery
bypass
<
Outdoor
air
temp.
-
Extract
air
temp.
<
Set
room
temperature
Temperature
to
enable
heat
recovery
bypass
To
enable
checking
of
the
other
parameters
for
bypass
mode,
the
outdoor
air
temperature
must
be
no
less
than
the
value
set
in
this
parameter.
Hysteresis
for
heat recovery
bypass
To
make
cooling
possible,
the
outdoor
air
temperature
must
be
cooler
than
the
extract
air
temperature
by
the
value
set
in
this
parameter.
Cooling/heating,
heat
recovery
bypass
Set the
purpose
for
which
the
bypass
should
be
used.
Option
Effect
Cooling/heating
Depending on
the
temperature,
use
the
outdoor
air
for
cooling
or
heating.
Cooling
Summertime:
use
cool
outdoor
air.
Heating
Spring/autumn:
use
warm
outdoor
air.
Frost
prot.
Frost protection
temp.
The
frost
protection
temperature
shows
you
the
switching
threshold
at
which
additional
heating
levels
are
switched
on.
Temp,
to
enable
frost
protection
The
unit
only
activates
frost
protection
if
the
outdoor
air
temper¬
ature
drops
to
the
value
that
can
be
set
in
this
parameter.
Enable
preheating
Option
Effect
Off
_
The
internal
preheater
is
completely
deactivated.
On
The
internal
preheater
is
activated.
To keep
the cross¬
countercurrent
heat
exchanger
free
from
ice,
pre¬
heating
ensures
a
minimum
supply
air
temperature
with
reference
to
the
temperature
that
is
set
in
the
_
"Frost
protection
temp."
parameter.
_
Frost protection
mode
Option
Effect
Outdoor
At
this
setting,
the
appliance
operates
solely
in
frost
air
reg.
protection
mode.
The
preheating
coil
control
only
_
measures
the
outside
temperature.
_
Passive
The
preheating
coil
is
controlled
to
ensure
that
the
house
supply
air
temperature
does
not
fall
below
the
16.5
°C
reg.
specified
in
the
passive
house
criteria.
_
Eco
To
save
energy,
the
flow
rate
of
the
appliance
is
re-
_
duced
when
the
preheating
coil
is
enabled.
_
Frost protection
stages
If
the
cross-countercurrent
heat
exchanger
freezes
up,
you can
combat
this
by
increasing
the
frost
protection
level.
Frost protection
volume
reduction
The
menu
item
is
relevant
only
for
troubleshooting
purposes.
With
this
function
you
can
select
how
the
appliance
should en¬
sure
frost
protection
at
the
output
limit
of
the
preheating
coil
or
without
the
preheating
coil.
The
appliance
is
pre-configured
such
that
the
ideal
operating
mode
is
preset.
Option
Effect
0_
Off
_
J_
No
function
_
2
Symmetrical
flow
rate
reduction
for
appliances
with
_
preheating
coil
_
3_
No
function
_
4
Asymmetrical
flow
rate
reduction
for
appliances
_
without
preheating
coil
_
5
Symmetrical
flow
rate
reduction
for
appliances
_
without
preheating
coil
_
Ventilation
unit
Device
type
Right-hand
version
_
Left-hand
version
_
0-10
V
input
Option
Meaning
0 Off
22
I
VRC-W
450/600
Premium
www.stiebel-eltron.com