Stiebel Eltron VRC-W 450 E Premium handleiding

308 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 21 van 308
Settings
(qualified
contractors)
Device
operating
time
This
value
shows
you
the
time
elapsed
since
the
appliance
was
commissioned.
Fan
operating
time
This
value
is
the
sum
total
of
all
the
time
during
which
the
fans
have
been
rotating
since
the
appliance
was
commissioned.
11.1.2
"Settings"
menu
View
The
only
parameters
displayed
in
the
standard
setting
are
those
that
are
enabled
for
the
appliance
user
and
can
therefore
be
ac¬
cessed
without
a
code.
Qualified
contractors
can
use
the
"View"
parameter
to
enable
actual
values
and
parameters
that
are
reserved
for
qualified
contractors.
Standard
The
only
parameters
displayed are
those
that
have
been
released
for
tne
appliance
user
and
_
can
therefore
be
accessed
without
a
code.
_
Expert
_
Parameters
for
contractors
(code
"1000")
_
Service
_
Parameters
for
service
department
_
To
enable
actual
values
and
parameters
that
are
reserved
for
qualified
contractors,
enter
the
code
"1000".
Press
"OK".
■=>
"Expert"
is
shown
on
the
display
once
this
has
been
entered
correctly.
If
you
switch
to
the
actual
values
or
parameters,
you
see
the
en¬
abled
parameters.
General
Temperature
sensor
If
you
want
the
current
room
temperature
and
room
humidity
to
be
displayed,
you
can
enable
the
programming
unit's
internal
temperature
sensor
with
this
parameter.
We
recommend
en¬
abling
this
parameter
only
if
an
external
programming
unit
is
connected.
Environment
sensor
If
you
require
demand-dependent
ventilation,
activate
the
C0
2
/
VOC
sensor
with
this
parameter.
If
the
preset
air
quality
limit
is
exceeded,
the
appliance
increases
the
air
flow
rate
to
reduce
the
VOC
value.
We
recommend
enabling
this
sensor
only
in
external
programming
units.
Air
flow
rate
Use
parameters
"Flow
rate,
stage
0"
to
"Flow
rate,
stage
3"
to
set
the
air
flow
rates
for
the
individual
fan
settings.
Flow
rate,
stage
0_ m3
/h
_
Flow
rate,
stage
1_ m3
/h
_
Flow
rate,
stage
2_ m3
/h
_
Flow
rate,
stage
3_ m3
/h
_
Offset
setting
Use
these
parameters
to
match
the
air
flow
rates
to
fan
settings
during
commissioning.
Unit
Value
Calculate
automatically
_
On
/
Off
Offset
supply
air
flow
rate
level
2_ m3
/h
_
Offset
extract
air
flow
rate
level
2_ m3
/h
_
Offset
supply
air
flow
rate
level
0_ m3
/h
_
Unit
Value
c:
CD
Offset
extract
air
flow
rate
level
0
m3
/h
Offset
supply
air
flow
rate
level
1
m3
/h
Offset
extract
air
flow
rate
level
1
m3
/h
Offset
supply
air
flow
rate
level
3
m3
/h
Offset
extract
air
flow
rate
level
3
m3
/h
In
parameter
"Calculate
automatically",
if
you
select
the
"On"
option,
the
supply
air
flow
rates
and
extract
air
flow
rates
are
calculated
internally
for
all
fan
settings
on
the
basis
of
the
stage
2
offset.
Alternatively,
you
can
enter
an
offset
value
individually
for
each
fan
setting.
Formula
for
calculating
internal
air
flow
rates
Internal
supply
air
flow
rate,
stage
0
=
offset
supply
air
flow
rate,
stage
0
+
supply
air
flow
rate,
stage
0
Example
of
automatic
calculation
Nominal
supply
air
flow
rate
(stage
2)
m3
/h
_
180
Offset
supply
air
flow
rate
stage
2_ m3
/h
_
45
This
example
shows
the
automatic
calculation
of
the
internal
set
air
flow
rates
on
the
basis
of
the
offset
for
stage
2.
0
50
50
X
1.25
=
62
1
130
130
X
1.25
=
162
2
180
45
180
+
45
=
225
/
1.
80
=
180
x
1.25
=
225
1.25
225
3
235
235
x
1.25
=
294
Humidity
prot.
Enable
humidity
control
With
humidity-dependent
flow
rate
control,
the
air
flow
rate
is
increased
or
decreased
depending
on
the
humidity
level.
Option
Effect
Off inactive
On
active
Humidity
prot.
Interval
If
you
set
fan
setting
0,
the
appliance
switches
to
a
24
hour
dormant
phase.
Only
after
this
will
humidity
protection
control
start.
The
appliance
measures
the
humidity
of
the
extract
air
for
the period
set
at
"Humidity
capture
delay".
The
unit
compares
the
last
measured
value
with
the
limit
value
set
at
"Humidity
threshold".
If
the
humidity
threshold
value
is
exceeded,
the
unit
starts
to
ventilate.
If
the
humidity
threshold
value
is
undershot
again,
the
unit
terminates
ventilation.
At
this
point,
the
humidity
protection
interval
starts
again,
at
the
end
of
which
the
moisture
is
measured.
Humidity
threshold
Set the
upper
limit
for
humidity
here.
Humidity
capture
delay
The
appliance
measures
the
humidity
of
the
extract
air
for
the
set
period.
The
unit
compares
the
last
measured
value
with
the
limit
value
set
at
"Humidity
threshold".
www.stiebel-eltron.com
VRC-W
450/600
Premium
|
21

Bekijk gratis de handleiding van Stiebel Eltron VRC-W 450 E Premium, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkStiebel Eltron
ModelVRC-W 450 E Premium
CategorieNiet gecategoriseerd
TaalNederlands
Grootte143775 MB