GAS SUPPLY REQUIREMENTS
Gas supply type MUST match the type of gas shown on the rating plate.
Gas supply pressure must NOT exceed 14” Water Column pressure and fall within the acceptable
pressure range shown below when using 1/2” NPT line and a 1/2” NPT connection.
Gas supply pressure must be between 5”-14” Water Column.
If the gas supply exceeds 14” Water Column, a pressure-regulating valve (pressure regulator) must be
installed in the gas supply plumbing to reduce pressure to the Steamer.
INSTALLATION OF THE GAS SUPPLY LINES
The installer/owner is responsible for furnishing and installing gas supply lines, valves, regulators and accessories.
When installing gas supply lines and accessories, observe the following:
Use a non-hardening pipe thread sealant resistant to LP gas.
The 1/2” NPT gas inlet is on the back of the steamer.
Install main manual shut-o valve between gas supply and the Steamer. This main manual shut-o valve
is called the “Main Manual Gas Valve”.
Install a sediment trap (drip leg) in gas supply line.
PRESSURE TESTING GAS SUPPLY LINES
If any pressure testing is required, the Steamer must be disconnected or isolated from the gas supply piping
system during any pressure testing as follows:
The appliance and its main manual shut-o valve must be disconnected from the gas supply piping
system during any pressure testing of the system at test pressures in excess of 14” Water Column ( PSI
or 3.45 kPa).
The appliance must be isolated from the gas supply piping system by closing its main manual shut-o
valve during any pressure testing of the gas supply piping system at test pressures in equal to or less
than 14” Water Column ( PSI or 3.45 kPa).
ELECTRICAL CONNECTIONS
The Sterling Manufacturing, LLC Steamer was designed, manufactured and tested to meet or exceed the strict
standards of safety and construction guidelines set forth by Underwriters Laboratories®. If any of these instructions
are not completely understood, or you have doubt as to whether your supply receptacle is of the correct voltage,
amperage or is properly grounded, consult a qualified electrician or serviceman.
INSTALLATION CODES AND STANDARDS
The Steamer must be installed in accordance with:
In the USA:
1. All State and Local Codes.
2. National Electric Code, ANSI/NFPA-70 (latest edition).
3. Vapor Removal from Cooking Equipment, NFPA-96 (latest edition).
In Canada:
1. All Local Codes
2. Canadian Electric Code, CSA C22.2 (latest edition).
WARNING: Electrical and grounding connections must comply with the applicable portions of
the National Electrical Code and/or other local codes.
!