Word Clock
The word clock connection panel of the optional AD converter
contains one clock input and output each as well as a switch
for terminating the clock input.
The AD converter processes incoming standard word clock
signals and generates them outgoing, thus ensuring perfect
digital transmission and the highest sound quality.
Tip: The termination switch should be pressed if the input is unassigned but the clock
output is being used as a clock source by an external device.
AD Converter Button
The AD converter button determines the sample rate and the
clock source.
The sample rate is the clock speed at which the unit is proces-
sing digital audio in samples per second. If WCLK is chosen,
the converter can be clocked through an external Word Clock
connected to the Word Clock Input.
The AD Converter button cycles through the available sample
rates and the external clocking option:
44.1kHz, 48kHz, 88.2kHz (44.1kHz x 2), 96kHz (48kHz x 2),
176.4kHz (44.1kHz x 4), 192 kHz (48kHz x 4)
and WCLK (external Word Clock)