Diagnostic Test Descriptions
Control Software Version Number Test d 1
This option displays the control software version number. To start
test, control must be in the Testing Mode. Refer to How to Enter
Testing Feature at the beginning of this section.
To enter, press the START (enter) keypad. The display will show
S XX where XX is the software version number.
To exit the Software Version Number Test, press the WARM (<)
keypad. The control will return to the Testing Mode.
Drive Board #1 Software Test d 3
This option displays the drive board software version number. To
start test, control must be in the Testing Mode. Refer to How to
Enter Testing Feature at the beginning of this section.
To enter, press the START (enter) keypad. The display will show
db1XX where XX is the software version number.
To exit the Drive Board #1 Version Test, press the WARM (<)
keypad. The control will return to the Testing Mode.
Water Level Trim Test d 7
This test checks the water level trim value. To start test, control
must be in the Testing Mode. Refer to How to Enter Testing Fea-
ture at the beginning of this section.
To enter, press the START (enter) keypad. The display will show
triNXX where XX is the trim value in 0.1 inch precision where a
value of 05 would equal 0.5 inches. If the right most decimal
point is lit, the trim value is negative.
To exit the Water Level Trim Test, press the WARM (<) keypad.
The control will return to the Testing Mode.
Service Door Opening Test d 8
This option tests the service door switch. To start test, control
must be in the Testing Mode. Refer to How to Enter Testing Fea-
ture at the beginning of this section.
To enter, press the START (enter) keypad. The display will show
S oP when the service door switch is open and S CL when the
service door switch is closed.
The service door switch has to be closed for at least one second
and opened for at least one second for the display to change. This
test will add a count to the service door opening counter for the
audit and save the date/time for each opening.
To exit the Service Door Opening Test, press the WARM (<) key-
pad. The control will return to the Testing Mode.
Coin Vault Opening Test d 9
This option tests the coin vault switch. To start test, the control
must be in the Testing Mode. Refer to How to Enter Testing Fea-
ture at the beginning of this section.
To enter, press the START (enter) keypad. The display will show
v oP when the coin vault switch is open and v CL when the
coin vault switch is closed.
The coin vault switch has to be closed for at least one second and
opened for at least one second for the display to change. This test
will add a count to the coin vault opening counter for the audit
and save the time/date for each opening.
To exit the Coin Vault Opening Test, press the WARM (<) key-
pad. The control will return to the Testing Mode.
Coin Drop 1 Input Test d 10
This option tests coin drop #1. To start test, control must be in the
Testing Mode. Refer to How to Enter Testing Feature at the be-
ginning of this section.
To enter, press the START (enter) keypad. The display will show
C1 XX. The XX will show the number of coins entered and will
increment one for each coin entered in coin drop #1.
NOTE: Coins entered in test mode will not increment
the total # of coins counter that is accessed in the audit
feature.
To exit the Coin Drop #1 Input Test, press the WARM (<) key-
pad. The control will return to the Testing Mode.
Coin Drop 2 Input Test d 11
This option tests coin drop #2. To start test, control must be in the
Testing Mode. Refer to How to Enter Testing Feature at the be-
ginning of this section.
To enter, press the START (enter) keypad. The display will show
C2 XX. The XX will show the number of coins entered and will
increment one for each coin entered in coin drop #2.
NOTE: Coins entered in test mode will not increment
the total # of coins counter that is accessed in the audit
feature.
To exit the Coin Drop #2 Input Test, press the WARM (<) key-
pad. The control will return to the Testing Mode.
Vend Connection Header Present Test d 12
This option tests the vend header connection. To start test, control
must be in Testing Mode. Refer to How to Enter Testing Feature
at the beginning of this section.
To enter, press the START (enter) keypad. The display will show
CH oP when the wiring connection is open and CH CL when the
connection is closed.
To exit Vend Connection Header Present Test, press the WARM
(<) keypad. The control will return to the Testing Mode.
Testing Machine and Electronic Control Functions
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
99 Part No. 807870ENR4