grammed value will not pause cycle time. This may result in low-
er max spin speeds and time.
1. Control must be in Manual Mode. Refer to How to Enter the
Manual Mode.
2.
Press the DELICATE () or the HOT () keypad until Prog
appears in the display. Press the START (enter) keypad, and
AtS 1 will appear in the display.
3. Press the DELICATE () or the HOT () keypad to scroll
through the programmable options until bAL At appears in
the display.
4.
When bAL At appears in the display, press the START (en-
ter) keypad. The current Number of Balance Attempts with no
Loss of Time will appear in the display.
5. Press the DELICATE () or the HOT () keypad to change
the current value. The factory default setting is 3.
6. Press the START (enter) keypad when the correct value ap-
pears in the display. The new value is saved and the next op-
tion will appear in the display.
Cycle Pause Resume CyCPAU
This option allows the owner to be able to pause a running cycle
when the START (enter) keypad is pressed 3 times within 5 sec-
onds during the first 3 minutes from the start of the cycle. Once
the control evacuates all water in the machine, it will unlock the
door. To resume the cycle, the door must be closed and then the
START (enter) keypad pressed. The cycle will continue from
where it left off.
1. Control must be in Manual Mode. Refer to How to Enter the
Manual Mode.
2.
Press the DELICATE () or the HOT () keypad until Prog
appears in the display. Press the START (enter) keypad, and
AtS 1 will appear in the display.
3. Press the DELICATE () or the HOT () keypad to scroll
through the programmable options until CyCPAU appears in
the display.
4.
When CyCPAU appears in the display, press the START (en-
ter) keypad. The current Cycle Pause Resume status will ap-
pear in the display.
on = Option Enabled
oFF = Option Disabled (factory default setting)
5. Press the DELICATE () or the HOT () keypad to change
the current status.
6. Press the START (enter) keypad when the correct value ap-
pears in the display. The new value is saved and the next op-
tion will appear in the display.
Low Power-Auto Shutdown 1 Days
Enable LPAS 1
This option allows the owner to set Low Power/Auto Shutdown
on certain day(s) of the week. Low Power and/or Auto Shutdown
days/duration are programmed using an external device or net-
work.
1. Control must be in Manual Mode. Refer to How to Enter the
Manual Mode.
2.
Press the DELICATE () or the HOT () keypad until Prog
appears in the display. Press the START (enter) keypad, and
AtS 1 will appear in the display.
3. Press the DELICATE () or the HOT () keypad to scroll
through the programmable options until LPAS 1 appears in
the display.
4.
When LPAS 1 appears in the display, press the START (en-
ter) keypad. The current Low Power/Auto Shutdown 1 Days
Enable status will appear in the display.
on = Option Enabled
oFF = Option Disabled (factory default setting)
5. Press the DELICATE () or the HOT () keypad to change
the current status.
6. Press the START (enter) keypad when the correct value ap-
pears in the display. The new value is saved and the next op-
tion will appear in the display.
Low Power-Auto Shutdown 2 Days
Enable LPAS 2
This option allows the owner to set Low Power/Auto Shutdown
on certain day(s) of the week. Low Power and/or Auto Shutdown
days/duration are programmed using an external device or net-
work.
1. Control must be in Manual Mode. Refer to How to Enter the
Manual Mode.
2.
Press the DELICATE () or the HOT () keypad until Prog
appears in the display. Press the START (enter) keypad, and
AtS 1 will appear in the display.
3. Press the DELICATE () or the HOT () keypad to scroll
through the programmable options until LPAS 2 appears in
the display.
4.
When LPAS 2 appears in the display, press the START (en-
ter) keypad. The current Low Power/Auto Shutdown 2 Days
Enable status will appear in the display.
on = Option Enabled
oFF = Option Disabled (factory default setting)
5. Press the DELICATE () or the HOT () keypad to change
the current status.
6. Press the START (enter) keypad when the correct value ap-
pears in the display. The new value is saved and the next op-
tion will appear in the display.
Programming Control
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
87 Part No. 807870ENR4

Bekijk gratis de handleiding van Speed Queen FV6010WN, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkSpeed Queen
ModelFV6010WN
CategorieWasmachine
TaalNederlands
Grootte14039 MB