Speed Queen FV6010WN handleiding

119 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 113 van 119
Error Codes
Display Description Cause/Corrective Action
E d 44
Overcurrent Shunt
Detection Circuit
Fail Error
Hardware failure. Unpower to clear error. Replace drive board if error persists.
E d 45
Door Lock Pin
HW On/Off Fail
Error
Hardware failure. Unpower to clear error. Replace drive board if error persists.
E d 46
Heater Pin HW
On/Off Fail
Hardware failure. Unpower to clear error. Replace drive board if error persists.
E d 47
Hot Valve Pin HW
On/Off Fail
Hardware failure. Unpower to clear error. Replace drive board if error persists.
E d 48
Cold Valve Pin
HW On/Off Fail
Hardware failure. Unpower to clear error. Replace drive board if error persists.
E d 49
Detergent Valve
Pin HW On/Off
Fail
Hardware failure. Unpower to clear error. Replace drive board if error persists.
E d 50
Softener Valve Pin
HW On/Off Fail
Hardware failure. Unpower to clear error. Replace drive board if error persists.
E d 51
Inrush Pin HW
On/Off Fail
Hardware failure. Unpower to clear error. Replace drive board if error persists.
E d 52
Voltage Doubler
Pin HW On/Off
Fail
Hardware failure. Unpower to clear error. Replace drive board if error persists.
E d 53
Door Lock Select
Voltage Pin HW
On/Off Fail
Hardware failure. Unpower to clear error. Replace drive board if error persists.
E d 54
Pump Pin HW
On/Off Fail
Hardware failure. Unpower to clear error. Replace drive board if error persists.
E d 55
Fatal NTC Short
Error
Check heater thermistor and thermistor wiring for damage. Unpower to clear error.
Replace drive board if error persists.
E d 56
Fatal NTC Open
Error
Check heater thermistor and thermistor wiring for damage. Unpower to clear error.
Replace drive board if error persists.
E d 63
Fatal IPM Temper-
ature Short Error
Hardware failure. Unpower to clear error. Replace drive board if error persists.
E d 64
Fatal IPM Temper-
ature Open Error
Hardware failure. Unpower to clear error. Replace drive board if error persists.
E d 67
ADC Current Not
Plausible Error
Hardware failure. Unpower to clear error. Replace drive board if error persists.
Error Codes
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
113 Part No. 807870ENR4