Preparations for the MPE-200 Unit
Chapter 2 Preparations
Preparations for the MPE-200 Unit
Connect the RS-232C port on the rear side of the MPE-200 unit to the serial port
of the computer, using an RS-232C cable. Then use the terminal software of the
computer to make the required settings for the MPE-200 unit.
Usage environment
RS-232C parameters:
Serial port setting
Rate 38,400 baud
Data word length 8 bit
Parity bit No
Stop bits 1 bit
Flow control No
Terminal settings:
VT100 type, 80 character × 24 lines or more
Establishing communication:
Confirm that “[syscon]$” appears on the terminal software.
Press the Esc key on the keyboard, and then press the Shift + C
within 1 second. Next, press the Enter key a few times. “localhost
login:” will appear and communication will start.
Logging in
To make settings, log in to the MPE-200 unit as a maintenance user account.
Maintenance user account information:
username: setup
password: sjx-311
After login is completed, the management software starts up automatically and
a console screen appears.
The following four items on the initial screen are not used when installing this
software.
• Application uninstall
• Factory Setting
• Platform update
• Log files collection
For details on these functions, please contact a Sony service representative or
dealer.
Verifying the Operating Environment of the MPE-200 Unit
Verify the versions of the firmware and software installed on the MPE-200 unit.
1
On the initial screen, select “4.”
Tip