Preparations for the MPE-200 Unit
Chapter 2 Preparations
Preparations for the MPE-200 Unit
Connect the RS-232C port on the rear side of the MPE-200 unit to the serial port
of the computer, using an RS-232C cable. Then use the terminal software of the
computer to make the required settings for the MPE-200 unit.
Usage environment
RS-232C parameters:
Serial port setting
Rate 38,400 baud
Data word length 8 bit
Parity bit No
Stop bits 1 bit
Flow control No
Terminal settings:
VT100 type, 80 character × 24 lines or more
Establishing communication:
Confirm that “[syscon]$” appears on the terminal software.
Press the Esc key on the keyboard, and then press the Shift + C
within 1 second. Next, press the Enter key a few times. “localhost
login:” will appear and communication will start.
Logging in
To make settings, log in to the MPE-200 unit as a maintenance user account.
Maintenance user account information:
username: setup
password: sjx-311
After login is completed, the management software starts up automatically and
a console screen appears.
The following four items on the initial screen are not used when installing this
software.
Application uninstall
Factory Setting
Platform update
Log files collection
For details on these functions, please contact a Sony service representative or
dealer.
Verifying the Operating Environment of the MPE-200 Unit
Verify the versions of the firmware and software installed on the MPE-200 unit.
1
On the initial screen, select “4.”
Tip