Clock synchronization with external devices — Clock settings
87
Setting the clock source
When set to INT (internal), the Ambient Ø acts as a clock master.
When not set to INT, the external device will be treated as the clock
master.
1
Press
func
+
CLOCK to select SRC.
2
Turn VALUE to set the clock source.
VALUE
Clock Source
INT
Use internal clock of LIVEN
Ambient Ø
MIDI
Use clock from MIDI IN
SYN C
Use clock from SYNC IN
LN .IN
Use clock from LINE IN
Setting Audio Sync output
Audio Sync output uses the headphone jack.
For this purpose, make the following setting to use Audio Sync out-
put.
1
Press
func
+
CLOCK and select A.OUT.
2
Turn VALUE to select ON.
・ The sync signal will be output from the left channel and a mono
mix of the audio will be output from the right channel of the
headphone jack.
A
.
O U T
S R C