Control unit
DIP switches
You can select di󰀨erent functions via the DIP switches. The following table
summarises the various setting options.
INFORMATION!
¾ All DIP switches are set to "OFF" in the factory settings
¾ To prevent damage to the DIP switches or the circuit
board, do not use sharp objects to change the position
of the DIP switches.
ON
1234
DIP switches Function E󰀨ect
1
OFF
Automatic closing
function
Disabled
Activated
ON
2
OFF
Power-saving mode
Activated
ON Disabled
3
OFF
No function
ON
4
OFF
No function
ON
Factory setting
Radio
Safety information for the radio remote control
DANGER!
If there is direct or indirect contact with live parts,
dangerous current could ow through the body.
Electrical shock, burns, or death may result.
¾ Before performing wiring work, make sure that the
lines are de-energised. During wiring work, make
sure that the lines remain de-energised (e.g. prevent
reactivation).
¾ Connection to the mains power must be performed by
the personnel described in the chapter "Qualications
of personnel" on page 6.
¾ The radio remote control may only be used for equipment and/or
systems where interference in the transmitter or receiver does not pose
a risk to humans, animals or objects, or where the risk is covered by
other safety devices.
¾ The radio remote control may only be used if the operator has a direct
view of the barrier and when there are no persons or objects within the
range of movement.
¾ Store the handheld transmitter of the radio remote control in such a way
that unintended operation e.g., by children or animals, is prevented.
¾ The operator of the radio system is not protected against interference
due to other telecommunications equipment or devices (e.g.: radio-
controlled systems that are licensed to operate in the same frequency
range). If substantial interference occurs, please contact your
appropriate telecommunications o󰀩ce which has radio interference
measuring (radio location) equipment!
¾ Do not operate the handheld transmitter in areas with sensitive radio
technology or systems (e.g. airports, hospitals).
CH1
CH3
CH2
CH4
RADIO
Explanation of the radio channels
LED Radio
channel
Setting/function
1 CH 1 Pulse mode
2 CH 2 Lighting function /
multi-function relay
3 CH 3 Defined OPEN
4 CH 4 Defined CLOSE