Sommer ASB-6010A handleiding
Handleiding
Je bekijkt pagina 33 van 61

33
Overview and ash sequences of the LEDs
The ash sequences provide information on malfunctions for the installer, the end customer and telephone support.
LED Flash sequence Cause
STATUS
(green)
O
• Normal mode
• Power-saving mode active / EMERGENCY STOP or targeted STOP
activated
• Force programming run in progress
• End positions not programmed
START 1
START 2
(orange)
O
• External command device is not activated
On
• External command device is activated
• Safety device in exterior interrupted/fault
SAFETY
(green)
O
• EMERGENCY STOP / targeted STOP activated
On
• EMERGENCY STOP / targeted STOP not activated
• Safety device interrupted in interior/fault
INDUC 1
(orange)
O
• Induction loop detector not activated
On
• Induction loop detector OFF activated
INDUC 2
(orange)
O
• Induction loop detector not activated
On
• Induction loop detector OFF activated
CLOCK
(orange)
O
• External command device not activated
On
• External command device activated
ALARM
(green)
O
• External command device not activated
On
• External command device activated
Photocell
(orange)
O
• No photocell detected
On
• Photocell detected
• Photocell interrupted / fault
WARNING
(orange)
O
• Barrier not in operation / no mains voltage
On
• Lights up during movement / pre-warning time activated
• Normal operation, blinks during movement
• Programming mode activated / pre-warning time during reversing
movement
• Waiting for conformation of the end position in programming mode
• Induction loop detector activated before or during movement / alarm
fault e.g. re alarm system activated
• Service required
Control unit
Bekijk gratis de handleiding van Sommer ASB-6010A, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Sommer |
Model | ASB-6010A |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |