5. Commissioning
User Manual
AC Coupling Scheme
Customers can integrate a new energy storage inverter (S6 Hybrid) to an existed Grid - tied
inverter system. Users can select two ways of AC Coupling connection modes. One is connect
the Grid –tied inverter to S6 inverter Gen port and another is on the backup Port.
(Tips: When the total system is at on-grid status, the grid-tied PV inverter MUST be connected
to the backup port of hybrid inverter. )
Time of Use Switch is for customizing when the battery is allowed to charge and discharge
power and at what rate, established by a current(amperage)setting.If this slid
er switch is
turned on, the inverter will only use this schedule to determine when to charge and discharge
the battery. If Allow Grid Charging is turned on, the inverter will use grid power to charge the
battery only under two circumstances:(1) the battery drains to the Force Charge SOC.
(2)Time of Use is enabled and there is not enough available PV power during the charge
window to meet the current rate that is established.
Time of Use is for manual control of the battery charging/discharging.If Time of Use is
turned off, charging/discharging is automatically regulated by the inve
rter.
AC Coupling on Backup port
PV Strings
Battery
PV Strings
Generator
Grid
APP
Data Stick
Back-UP Load Loads
Power MeterSmart Meter
Soliscloud
Hybrid Inverter
PV Inverter
DC
AC Internet Bluetooth
RS485 Communication Cable Communication