Solis S6-EH3P15K02-NV-YD-L handleiding
Handleiding
Je bekijkt pagina 40 van 68

37
5. Commissioning
User Manual
Off-Grid Mode
Off-grid Mode Switch
Off-grid Overdischarge SOC
30%
>
Off-Grid Mode is only to be used by systems that are not electrically connected to the grid
at all. This mode is like Self-Use Mode, but the PV power will be curtailed if the battery is
charged and the home load demand is lower than the amount of available PV power.
Backup Mode can be opened in the Self-Use or Feed in Priority Mode. What this mode does
is ensure that the battery does not drain past the Reserve SOC(state-of-charge) percentage.
The battery will cycle between 100% and the Reserve SOC, so if grid power is lost, the battery
will have the Reserve SOC at the very least to carry the home through the outage.
Peak-shaving Mode: Peak-shaving function is possible to set the maximum power (Pmax)
that the system obtains from the main grid. The power of the main grid charges batteries and
supplies power to the load, which is within (Pmax). When the load power exceeds the set
maximum power (Pmax), the insufficient part is provided by the battery. At the same time,
users can set the Peak SOC and charge the battery to this SOC as far as possible under the
premise of satisfying Pmeter.
(Tips: Only the lithium battery with CAN connection support the peak-shaving mode)
Peak-shaving Mode
Peak-shaving Mode
Note: This mode only support the use with lithium
batteries with communication
Max.useable Grid Power
Baseline SOC
Charging & Discharging Setting
Allow Grid Charging
+ Add Time
70%
>
3000W
>