3.10 Inverter Communication
User Manual
3. Installation
3.10.1 Communication Ports
Port
COM1
COM2
COM3
COM4
DescriptionPort Type
USB
6 hole watertight cable gland
4 hole watertight cable gland
Used for Solis data logger connection
Used for 16 PIN terminal block connection
inside wiring box
Used for RJ45 connection inside wiring box
Wiring steps for COM2-COM5:
Step 1. Loose the cable gland and remove the watertight caps inside the cable gland based
on the number of the cables and keep the unused holes with watertight cap.
Step 2. Lead the cable into the holes in the cable gland.
(COM2-COM3 Hole Diameter: 6mm, COM4-COM5 Hole Diameter: 2mm)
Step 3. Connect the cable to the corresponding terminals inside the wiring box.
Step 4. Reassemble the cable gland and ensure there is no bending or stretching of the cables
inside the wiring box.
NOTE:
The 4-hole fastening rings inside the cable
gland for COM2 and COM3 are with openings
on the side.
Please separate the gap with hand and squeeze
the cables into the holes from the side openings.
21
COM5
4 hole watertight cable gland
Used for RJ45 connection inside wiring box
6 hole watertight cable gland
Used for 16 PIN terminal block connection
inside wiring box