Sime Murelle 70 Box ErP handleiding

56 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 22 van 56
22
able before activating chimney sweep).
If the key
5
3
1
2
4
and
5
3
1
2
4
are pressed during
the 15 minutes of the chimney sweep func-
tion, the boiler will be brought respectively
to maximum and minimum power.
The chimney sweep function will automat-
ically switch off after 15 minutes or when
the key
5
3
1
2
4
is pressed again.
4.5.2 Operation floor drying (fig. 22)
The operation floor drying keeps the floor
at a pre-established temperature profile
and it is activated only for those systems
combined with the mixed zone card MIXED
ZONE code 8092275/76.
The temperature profiles can be selected
by means of the installer parameter PAR
43:
0 = Not activated function
1 = Curve setting A
2 = Curve setting B
3 = Curve setting A + B
The turning off of the function happens
clicking on the button OFF (return of PAR
43 to the value 0) or automatically at the
end of the function.
The set of the mixed zone follows the
development of the selected curve and
reaches a maximum of 55°C.
During the function all the other heating
demands are ignored (heating, sanitary,
antifreeze and chimney sweep).
During the functioning the display shows
the remaining days for the completion of
the function (example mains digits -15 = 15
days lack to the end of the function). The
diagram fig. 22 reports the development of
the curve.
ATTENTION:
- Observe the relevant standards and
regulations of the floor manufacturer!
- Proper functioning is ensured only
when the plant is correctly installed
(hydraulic system, electrical installa-
tion, settings)! If not observed, the floor
might get damaged!
50
45
40
35
30
20
5101518
[Tag
]
0
25
55
AB
11
57
X
A + B
1 25
[TVw]
Fig. 22
TVw Flow temperature setpoint
Tag Period in days
x Start day
A Functional heating
B Floor curing heating
Apre
2
2
2
Circuito
riscaldamento 2
Circuito
riscaldamento 3
(impianto tre
zone)
Fig. 21