4 DESCRIPTION OF THE APPLIANCE
4.1 Characteristics
HYBRID REVOLUTION 30
is an innovative Class A+ low-tempera-
ture hybrid wall-mounted heat pump that
Sime
has built ONLY
for space heating and for the production of instantaneous do-
mestic hot water.
It is made up of a lat
es
t-generation sealed condensing gas boil-
er and a heat pump.
HYBRID REVOLUTION 30
can work also when it is not connect-
ed to the outdoor probe, as it detects the outdoor air incom-
ing value. If the outdoor air temperature probe is added, the
measur
ed v
alue may be more precise but will not have any
impact on the machine’s correct operation.
The wall the appliance is mounted to must be able to support its
weight, and preferably be an outside wall, to simplify installing
the air inlet and outlet pipes.
HYBRID REVOLUTION 30
can produce water for a heating system
to a temperature of up to 75°C.
To obtain maximum performance
from
HYBRID REVOLUTION 30
, the delivery temperature
MUST
NOT
exceed
65°C
and the return temperature must not be above
of
45°C
.
The main design choices made by
Sime
for
HYBRID REVOLUTION
30
boilers are:
– use of a sealed boiler with a total pre-mix microflame burner
combined with a steel heat exchanger body and a rapid heat
exchanger for DHW
– use of a modulating circulation pump
– the use of a heat pump (HP) that is integrated by the boiler to
produce heat and can operate separately or simultaneously
with the boiler, depending on the temperature measured by
the outdoor air temperature probe
– a Main control panel (remote control) which serves both as
an room thermostat and as a command and control device, a
microprocessor, with bus protocol to manage the
HYBRID REV-
OLUTION 30
and related system
– a main evaporator with a patented fume evaporator in series
and plate heat exchanger for transmitting heat to the system
water. The entire assembly allows the heat pump to work with
an average CoP of 4.
– the option of being connected to room thermostats or
chrono-thermostats for the zone.
HYBRID REVOLUTION 30
also has the following functions:
– the anti-freeze function which is activated automatically if the
temperature of the water inside the boiler falls below the val
-
ue set under “PAR 10” and if the outdoor temperature falls
below the value set under “PAR 11”
– the anti-blocking function of the pump and diverter valve, this
activates automatically every 24 hours if no request for heat
has been made
– the chimney sweep function lasts 15 minutes and makes the
job of the qualified technician easier when measuring the pa
-
rameters and combustion efficiency
–
domestic hot water comfort function which allows the time
necessary for the hot water to become available to be reduced
and ensures that the temperature is stable
– screen display of the operating and self-diagnostic parame
-
ters with error code display when the fault occurs. This makes
r
epair int
erventions easier and allows appliance operation to
be restored correctly.
4.2 Operation summary
4.2.1 Heating
When there is a heating request from the main control panel
(Pcp) or from an room thermostat for the zone (TZ), where there
are no alarms and where the outdoor temperature is at least
-7°C, the heat pump is activated (HP).
After a set period of time, calculated using an algorithm ac
-
cording to the current outdoor temperature, the gas boiler also
s
t
arts up to help heat the water in the system and respond to the
current request for heat.
When the system water temperature reaches the required val
-
ue, also calculated using a specific algorithm for the gas boiler,
the boiler s
tops and ONLY the heat pump continues to operate,
until the heating request has been satisfied; after which, the
heat pump also stops.
m
CAUTION
If, when there is a heating request, the outdoor tem-
perature is
below -7°C (e.g. - 10°C)
, only the gas boiler
is activated and the heat pump remains inactive.
4.2.2 Domestic Hot Water (DHW)
When there is a request for DHW, providing there is no heating
request from the room thermostats, the diverter valve prepares
to direct the flow of water towards the plate heat exchanger and
the boiler starts up to respond to the request.
Should there be a request for heat at the same time, the heat
pump stops and the boiler operates as described above. Once
the DHW request has been satisfied, standard heating operation
resumes.