Sime FUEL EV handleiding

100 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 56 van 100
56
EN
6 MAINTENANCE
6.1 Adjustments
Periodic maintenance is MANDATORY BY LAW and is important
for the safety, efficient operation and long-lasting life of the
burner, while it also helps to reduce consumption and polluting
emissions.
We therefore recommend the user to entrust a professionally
qualified technician to carry out maintenance on the appliance
on an
ANNUAL
basis.
m
CAUTION
The operations described below must ONLY be car-
ried out the professionally qualified personnel
who
MUST wear
suitable accident-prevention equipment.
Make sure that the temperature of the components
inside the device or of the system pipes are not too
hot (risk of burns).
Shift the main switches of the system and of the
boiler to “OFF”.
Close the fuel shut-off valve.
OFF
Fig. 33
6.2 Removing the burner
To remove the burner form the boiler, proceed as follows:
loosen the nut (9) fastening the burner to the boiler;
turn the burner (10) slightly to the right and extract it from
the boiler;
10
9
Fig. 34
loosen the two screws (1) and slide off the cover (2);
2
1
1
Fig. 35
detach the 7-pole plug (1) from the burner.
1
Fig. 36