4.7. Power Linking of Multiple Devices
This device supports power linking. Power can be relayed to another device via the power OUT connector.
Note that the input and the output connectors have different designs: one type cannot be connected to the
other.
Power linking of multiple devices must be carried out only by instructed or skilled persons.
WARNING
Incorrect power linking may lead to overload of the electrical circuit and result in serious
injuries and damage of property.
To prevent overload of the electrical circuit, when power linking multiple devices:
•
Use cables with sufficient current-carrying capacity. The power cable supplied with the device is not
•
suitable for power linking of multiple devices.
•
Make sure that the total current draw of the device and all connected devices does not exceed the rated
•
capacity of the power cables and the circuit breaker.
•
Do not link more devices on one power link than the maximum recommended number.
•
Maximum recommended number of devices:
• at 100–120 V: 3 devices Performer Fresnel 2200 DDT•
• at 200–240 V: 6 devices Performer Fresnel 2200 DDT•
Note:
The calculation of the maximum recommended number of devices is based on a power output of 16 A. This
can be less if the device is connected to a dimmer pack.