Handleiding
Je bekijkt pagina 36 van 158

English - 34
11. Wiring
(1)
Maximum number of signal connections
The maximum number of connections per LAN cable is shown below.
Product name Maximum number of connections
LD-E121 4 displays
LD-E151 7 displays
LD-E181 10 displays
LD-E251 17 displays
CAUTION
The maximum number of connections may differ depending on the connected LED controller. Therefore,
check the specifications of the LED controller you are using.
Ask a technician or your retailer for more details.
(2)
Maximum number of power connections
CAUTION
Exceeding the maximum capacity may generate smoke or cause a fire.
Check the voltage used and do not exceed the connection limits shown below.
Product name 100 - 120 V AC
200 - 240 V AC
LD-E121 18 displays 40 displays
LD-E151 22 displays 50 displays
LD-E181 22 displays 50 displays
LD-E251 18 displays 40 displays
AC 100 V AC 200 V
Inrush current
25°C Cold start
Pulse width: 3ms
per 1 display 30 A 60 A