REFRIGERATED DROP-IN WELLS
USER MANUAL
Hole-cutting should be done by a professional. The counter must be able to hold the weight of the unit. The surface must
be level to have even force supporting the case. When drop-in units are being installed, they should be lowered down from
both sides so that they are level.
The cutout into the cabinet must have a minimum of 4” from each edge of the countertop to properly support the
drop-in well. The condenser shroud may need to be removed to drop into cabinetry.
The cabinet cannot be completely closed off. There must be air flow for the refrigeration to breathe and function.
INSTALLATION DIMENSIONS
DIMENSIONS BELOW ARE NOMINAL AND MAY VARY BASED ON MANUFACTURING TOLERANCES. IT IS RECOMMENDED TO ALWAYS
MEASURE THE ACTUAL UNIT RECEIVED PRIOR TO PROCEEDING WITH CUTOUT AND INSTALLATION.
Item #
Total Height
(Including
Condensing
Unit)
Overall Outer Dimensions
(Flange)
Overall Outer Dimensions
(No Flange)
Suggested Cutout Size
Flange
Overhang
(Per Edge)
Width Depth Width Depth Width Depth
Diagram
Reference
A
B C D E F G
H
423SDC1A
22
1
/
16
"
(560mm)
16 ½"
(419mm)
25 ⅞"
(657mm)
15 ¼"
(387mm)
24 ⅝"
(625mm)
15 ½"
(393mm)
24 ⅞"
(631mm)
"
(16mm)
423SDC2A
29 ⅝"
(752mm)
28 ⅜"
(720mm)
28 ⅝"
(726mm)
423SDC3A
42
13
/
16
"
(1087mm)
41
9
/
16
"
(1055mm)
41
13
/
16
"
(1061mm)
423SDC4A
56 ¼"
(1429mm)
55"
(1397mm)
55 ¼"
(1403mm)
423SDC5A
69 "
(1775mm)
68 ⅝"
(1743mm)
68 ⅞"
(1749mm)
423SDC6A
83
7
/
16
"
(2119mm)
82
3
/
16
"
(2087mm)
82
7
/
16
"
(2093mm)
Before getting started, please refer to the Installation Diagrams on page 8.
GENERAL NOTE: All electric units to be connected and installed must comply with NEC and local codes. Consult a qualified
plumber for proper trap and drain installation that complies with local plumbing codes.
1. Cut out countertop as specified.
NOTE: Unit is designed for installation in stainless steel countertops. If installed in stone or wood countertop, additional
clearances between the well and the counter are necessary.
2. Apply putty or butyl tape to the underside perimeter of the well rim outer edge.
3. Apply a ¼” bead of food-grade silicone adjacent to the putty/butyl tape on the well flange.
4. Drop well into the pre-cut opening from the top and push down until the perimeter of the well flange is flush with the
counter service.
5. Allow silicone to set and fully cure before making electric and water connections.
6. Attach drain using rubber coupling or PVC unit to drain.
NOTE: Copper drain lines are recommended.