ServIt 423SDC5A handleiding

9 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 5 van 9
5
TM
REFRIGERATED DROP-IN WELLS
USER MANUAL
CONTROL PANEL
(CONTINUED)
Electrical
Please ensure that the required voltage is being supplied at all times.
The unit should be plugged into a grounded and properly-sized electrical outlet with appropriate over-current protection.
Please refer to the electrical requirements on the units nameplate.
The unit should have its own dedicated outlet.
Do not use extension cords.
Ensure the unit is not resting on or against the electrical cord.
If the unit is not in use for a long period of time, please unplug the unit from the outlet.
To avoid shock and fire hazards, do not plug in or unplug the unit with wet hands.
After unplugging the unit, wait at least 10 minutes before plugging it back in. Failure to do so could damage the compressor.
Defrost System
Refrigeration units contain an automatic defrost system. Refrigeration coils are kept below the freezing point (32º F). When
defrosting the unit, run-off water will drain out the bottom of the unit. Verify that drain hose leads to a container, drain, or pump.
OPERATING INSTRUCTIONS
WE STRONGLY RECOMMEND THAT ANY SERVICING BE PERFORMED BY AN AUTHORIZED SERVICE TECHNICIAN.
DISCONNECT POWER CORD BEFORE CLEANING ANY PARTS OF THE UNIT.
Loading Product
DO NOT BLOCK THE AIR VENTS.
Ensure all shelves are sitting level and properly secured before loading products.
Do not store flammable and explosive gas or liquids inside the unit.
Cleaning the Condenser Coil
A DUSTY CONDENSER MAY LEAD TO HIGH ENERGY CONSUMPTION, LESS COOLING EFFECTIVENESS, AND COMPRESSOR DAMAGE.
THE CONDENSER COIL IS LOCATED AT THE BOTTOM BEHIND THE PANEL.
1. Disconnect the electrical power from the unit.
2. Remove the front cover and base cover with a screwdriver.
3. Using a soft brush and/or vacuum, remove the dirt, lint, etc. from the finned condenser coil in a vertical direction.
4. Clean the condenser with a commercial condenser coil cleaner, available from any kitchen equipment retailer.
(Example: Nobel Chemical Tech Line)
5. After cleaning, straighten any bent condenser fins with a fin comb.
6. When finished, be sure to reinstall the front cover and base cover.
7. Reconnect the electrical power to the unit.
Cleaning the Fan Blades and Motor
If necessary, clean the fan blades and motor with a soft cloth.
If it is necessary to wash the fan blades, cover the fan motor to prevent moisture damage.