XPT800 Sound Level Meter and Spectrum Analyzer
V1.0
Page 33 of 124
5.4.2 Windscreen
When making outdoor measurements in windy weather or when making measurements on air condi-
tioning equipment, wind noise or air movement against the microphone can generate measurement
errors. Such effects can be reduced by using a wind protection bonnet.
To avoid possible measurement errors, use the windscreen on the microphone, especially when there
is strong wind or substantial airflow generated by equipment.
Info
Since the wind shield can protect the microphone from accidental shocks, it is recommend-
ed to use it even during indoor measurements.
Fig. 10 - Assembly and disassembly of windscreen
5.4.3 Outdoor microphone unit
Disassembly of the Unit is necessary to perform, for example, calibration (partial disassembly only) or
cleaning.
Info
To pull out the top of the unit and perform calibration, follow steps 2 and 3.
See the outdoor microphone unit manual for more information.
To completely disassemble the unit, you need to have a 2 mm hexagonal Allen wrench.
1
Unscrew the unit from the holder 1/2W or 1/4W, if any.
2
Using the Allen wrench, loosen the grub screw securing the top (A) of the protection.
3
Disconnect the upper part (A) of the guard from the lower part (B) by pulling it off the sensor (D);
be careful not to damage the sensor.
4
To completely remove the sensor (D), disconnect it, via push-pull connector, from the extension
cable (E) and pull the cable out by passing the connector through the hole (F).
To perform the assembly, proceed in the reverse way.