ECO 410 / ECO 410T - O2-Analyser / oxygen meter
Operation
B-H86.0.31.DK2-2.1 Page 10 of 22
4 Operation
4.1 Opening the configuration menu
1 Press the Function button for 2 seconds to open the Configuration menu.
2 (ONF appears in the display. Release the Function button.
Parameter
Values
Meaning
INP
Auxiliary display (only available at ECO 410T)
%
02
No auxiliary display,
only display of the oxygen concentration in [vol. %]
m
80D
Auxiliary display:
maximum operational depth MOD in meter [m] sea
water (for explanation of MOD see #1).
FT
80D
Auxiliary display:
maximum operational depth MOD in feet [ft] sea
water (for explanation of MOD see #1).
P.ABS
Air pressure
500 .. 12000
Air pressure in [hPa] corresponds to [mbar]
(note explanation #2 )
PO2
Max. Oxygen partial pressure (only available at ECO 410T)
0.2 ... 1.6
Partial pressure in [bar]
(Observe extended notes #3 !!)
POFF
Shut-off time
OFF
No automatic shut-off
0:15, 0:30, 1:00, 4:00,
12:00
Automatic shut-off after a selected time in
hours:minutes, during which no buttons have been
pressed
L,TE
Backlight
OFF
Backlight deactivated
0:15, 0:30, 1:00, 2:00,
4:00
Automatic shut-off of the backlight after a select-ed
time in minutes:seconds, during which no buttons
have been pressed