2. Apply the adhesive to the sealer’s sealing platform. Tuck the adhesive close to the mounting screw
as possible. Note: The PTFE adhesive serves as a barrier between the sealer body and element.
Never allow the element to come in direct contact with the sealer body. A good rule of thumb is
to replace the PTFE adhesive every time you change the element.
3. Hook one end of the element to the mounting screw. Place the sealer on its side so that
mounting screw is touching the table. To attach the element to the other side, press down on the
mounting screw while at the same time use a screw driver to press down on the mounting screw
on the other side of the sealer. Both mounting screws should be held down at the same time and
this will allow you to attach the other end of the element. Attach cap and nut.
4. Replace the PTFE cover.
5. Replace the PTFE cover on both sides. Tighten the screws on the PTFE cover plates when the
PTFE cover is position smoothly on top of the element. Note: The PTFE cover prevents the
plastic or any thermoplastic material you are sealing from sticking to the heating element.