UC GOURMET UNDERCOUNTER
pg. 17
4. REFRIGERANT METERING DEVICE
Capillary Tube
5. COMPONENTS DESCRIPTION
a. Evaporator Temperature Sensor
The evaporator temperature sensor probe, located in contact with the evaporator
serpentine, detects the dropping of the evaporator temperature during the freeze cycle and
signals it by supplying a current flow to the microprocessor of the PC Board. According to the
current received, the small red LED of the PC Board is energized (blink or steady). When
steady, the microprocessor supplies power to the electronic timer built into the PC Board so
that it takes control of the last portion of the freeze cycle. The length of the timed phase is pre-
fi
xed by the setting of the keys 1, 2, 3, and 4 of the DIP SWITCH.
If after 15 minutes from the beginning of the freeze cycle, the evaporating temperature has not
yet reached 32˚F (0˚C) – small red LEF OFF – the PC Board switches OFF the machine with the
blinking of WARNING RED LED.