Scheppach HC24x handleiding

288 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 24 van 288
www.scheppach.com
24
|
GB
Do not deploy the compressor in damp or wet areas.
Operate the compressor only in suitable areas (well
ventilated, ambient temperature +5°C to 40°C).
There must be no dust, acids, vapours, explosive
gases or inammable gases in the room.
The compressor is designed to be used in dry
rooms. It must not be used in areas where splashed
water is present.
The compressor may only be used outdoor briey
when the ambient conditions are dry.
The compressor must always be kept dry and must
not be left outdoors after work is complete.
8. Assembly and operation
m Attention!
Always make sure the device is fully assembled
before commissioning!
You require the following for assembly:
Open-ended spanner (not included in the scope of
delivery)
8.1 Fitting the foot (Fig. 2 / 2.1)
Fit the foot (10) provided as shown in Figure 2.1.
8.2 Fitting the wheels (Fig. 3 / 3.1)
Fit the wheels (8) provided as shown in Figure 3.1.
9. Commissioning
9.1 On/O󰀨 switch (Fig. 1)
Set the On/O󰀨 switch (6) to I to switch on the compres-
sor. Set the On/O󰀨 switch to O to switch o󰀨.
9.2 Adjusting the pressure: (Fig. 5)
The pressure at the manometer (4) is adjusted with the
pressure regulator (3).
The pressure set can be drawn from the quick coupling
(2).
The vessel pressure can be read o󰀨 at the pressure
gauge (4).
The vessel pressure is taken at the quick-coupling (2).
9.3 Relieving the overpressure after work is
complete
Release overpressure in the compressor by switching
o󰀨 the compressor and using up the compressed air
still in the pressure vessel, e.g. with a compressed air
tool running at idle or with an air blow gun.
6. Technical data
Mains power connection 220 - 240 V~ / 50 Hz
Engine output 1200 W
Operating mode S3 25%
Compressor speed 3800 rpm
Pressure vessel volume 24 l
Operating pressure approx. 8 bar
Theo. Suction capability approx. 180 l/min
Theo. Power output approx. 96 l/min
Protection category IP30
Device weight approx. 15 kg
Max. installation altitude
(above sea level)
1000 m
S3 25% = periodical intermediate duty with a duty cycle
of 25% (2.5 min based on a 10 minute period)
The noise emission values have been determined in
accordance with EN ISO 3744.
Wear hearing protection.
Excessive noise can result in a loss of hearing.
m Warning: Noise can have serious e󰀨ects on your
health. If the machine noise exceeds 85 dB, please
wear suitable hearing protection.
Sound power level
L
wA
97 dB
Sound pressure level L
pA
76.17 dB
Uncertainty K
wA/pA
0.73 dB
7. Before commissioning
Before connecting the machine, make certain that
the data on the type plate matches with the mains
power data.
Check the device for transport damage. Report
any damage immediately to the transport company
which was used to deliver the compressor.
Install the compressor near the point of consumption.
Long air lines and supply cables (extension cable)
should be avoided.
Ensure that the intake air is dry and dust-free.

Bekijk gratis de handleiding van Scheppach HC24x, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkScheppach
ModelHC24x
CategorieNiet gecategoriseerd
TaalNederlands
Grootte40205 MB