AC motor 230 V~ / 50 Hz
Mains voltage 230 V~ / 50 Hz.
Mains power connection and extension leads must be
3-core = P + N + SL. - (1/N/PE).
Extension leads up to 25 m must have a minimum
cross-section of 1.5 mm².
The mains power connection must be protected with a
max. 16 A fuse.
Connection type Y
If it is necessary to replace the mains connection ca-
ble, this must be done by the manufacturer or their rep-
resentative to avoid safety hazards.
12. Cleaning and maintenance
m Attention!
Only carry out maintenance, cleaning and adjustment
work when the mains plug is pulled out.
We recommend that you clean the product directly af-
ter every use.
Clean the product at regular intervals using a damp cloth
and a little soft soap. Do not use any cleaning products or
solvents; they could attack the plastic parts of the prod-
uct. Make sure that no water can penetrate the motor.
We recommend regular inspections and care for a
long service life.
Before extended periods of inactivity or through the
winter, the pump should be thoroughly ushed through
with water, emptied completely and then stored dry.
To empty the pump housing, loosen the water drain
screw (5) and tilt the pump slightly.
If there is a risk of frost the pump must be completely
emptied.
After longer periods of storage check the pump by
switching on/off briey in order to check that the ro-
tor turns normally.
In the event of the pump being jammed connect the
pressure line to the water supply line and remove the
suction hose. Open the water supply line. Switch the
pump on for ca. two seconds several times. This meth-
od recties blockages in most cases.
To clean the pre-lter (8), loosen the pre-lter screw
(7) and remove it. Afterwards, clean it with clear water.
5. Switch the product off at the on/off switch (3) when
you have nished working.
m NOTE!
The pump must be absolutely tight at the inlet and out-
let. Therefore, regardless of your chosen connection,
use a Teon or any other sealing tape.
11. Electrical connection
The electrical motor installed is connected and ready
for operation. The connection complies with the appli-
cable VDE and DIN provisions.
The customers mains connection as well as the ex-
tension cable used must also comply with these reg-
ulations.
Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
Pressure points, where connection cables are
passed through windows or doors.
Kinks where the connection cable has been improp-
erly fastened or routed.
Places where the connection cables have been cut
due to being driven over.
Insulation damage due to being ripped out of the wall
outlet.
Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly. Ensure that the connection cables are dis-
connected from electrical power when checking for
damage.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables of the same designation.
The printing of the type designation on the connection
cable is mandatory.
For single-phase AC motors, we recommend a fuse
rating of C 16A or K 16A for products with a high start-
ing current (from 3000 watts)!