English-29
INSTALLATION
05
Outdoor Unit
Where it is not exposed to strong wind
Well ventilated and dustless places
Where possible keep out of sunlight and rain
Where neighbors are not annoyed by operation sound or hot air
Solid wall or support that prevents vibration and is strong enough to hold the product weight
Where there is no risk of flammable gas leakage
When installing the unit at a high place be sure to fix the unit legs
3 m or more away from the TV or radio (to prevent the screen from being distorted or noise from being generated)
Install the unit horizontally
Place where drained water does not become any problem.
Place with no plants (especially climbing plants) and where small animal can not access.
Outdoor unit should not be place higher than 2.4 m or directly under eaves for accessibility for service and OH&S reasons.
Avoid the following places to prevent malfunction of the unit
- Where there is machine oil
- Salty environment such as seaside areas
- Where sulfide gas exists - Other special atmosphere areas
CAUTION
The appearance of the unit may be different from the diagram depending on the model.
A
Outdoor
Unit
Indoor
Unit
125 mm or mor
e
Wrap the refrigerant pipes and the drain hose
with the absorbent pad and vinyl tape.
Refer to page 45 for further details.
' 15' met
ers maximum total
pipe length
Make at least one round: It will help reduce noise and vibration.
'5' meters maximum
total pipe height
100 mm or more
125 mm or more
Cut insulation to have
rainwater drained
You can select the direction
of draining (left or right).
Outer wall
'15' m as maximum pipe length
and 3 m as minimum pipe length.
(It will reduce noise and vibration)
CAUTION
Make an U-trap(A) on the pipe (which is connected to the
indoor unit) at outer wall and cut the bottom part of the
insulation (about 10 mm) to prevent rainwater from getting
inside through the insulation. However, be careful not to
damage the pipe.
CAUTION