5. Wrap it with the insulation tape twice or more and position your contraction tube in the middle of the
insulation tape.
Three or more layers of insulation are required.
f Method 1
40 mm
Insulation tape
f Method 2
Insulation tape
35 mm
6. Apply heat to the contraction tube to contract it.
Contraction tube
7. After tube contraction work is completed, wrap it with the insulation tape to nish.
CAUTION
• Make sure that the connection parts are not exposed to outside.
• Be sure to use insulation tape and a contraction tube made of approved reinforced insulating
materials that have the same level of withstand voltage with the power cable. (Comply with the
local regulations on extensions.)
Insulation tape
WARNING
• In case of extending the electric wire, please DO NOT use a round-shaped Pressing socket.
- Incomplete wire connections can cause electric shock or a re.
Extending the power cable