Safety Information
Labelling
• The parts shall be labelled to ensure that they have
been decommissioned and emptied of refrigerant.
• The labels shall be dated.
• Make sure that the labels are affixed on the system to
notify it contains flammable refrigerant.
Recovery
• When removing refrigerant from the system for
servicing or decommissioning, it is recommended to
remove the entire refrigerant.
• When transferring refrigerant into cylinders, make sure
that only the refrigerant recovery cylinders are used.
• All cylinders used for the recovered refrigerant shall be
labelled.
• Cylinders shall be equipped with pressure relief valves
and shut-off valves in a proper order.
• Empty recovery cylinders shall be evacuated and cooled
before recovery.
• The recovery system shall operate normally according
to the specified instructions and shall be suitable for
refrigerant recovery.
• In addition, the calibration scales shall operate normally.
• Hoses shall be equipped with leak-free disconnect
couplings.
• Before starting the recovery, check for the status of the
recovery system and sealing state. Consult with the
manufacturer if suspected.
• The recovered refrigerant shall be returned to the
supplier in the correct recovery cylinders with the Waste
Transfer Note attached.
• Do not mix refrigerants in the recovery units or
cylinders.
• If compressors or compressor oils are to be removed,
make sure that they have been evacuated to the
acceptable level to ensure that flammable refrigerant
does not remain in the lubricant.
• The evacuation process shall be performed before
sending the compressor to the suppliers.
• Only the electrical heating to the compressor body is
allowed to accelerate the process.
• Oil shall be drained safely from the system.
• For installation with handling the refrigerant (R-32),
use dedicated tools and piping materials. Because
the pressure of the refrigerant, R-32 is approximately
1.6 times higher than that of R-22, failure to use the
dedicated tools and piping materials may cause rupture
or injury. Furthermore, it may cause serious accidents
such as water leakage, electric shock, or fire.
• Never install a motor-driven equipment to prevent
ignition.
Power supply line, fuse or circuit
breaker
WARNING
• Always make sure that the power supply is compliant
with current safety standards. Always install the air
conditioner in compliance with current local safety
standards.
• Always verify that a suitable earthing connection is
available.
• Verify that the voltage and frequency of the power
supply comply with the specifications and that the
installed power is sufficient to ensure the operation of
any other domestic appliance connected to the same
electric lines.
• Always verify that the cut-off and protection switches
are suitably dimensioned.
• Verify that the air conditioner is connected to the power
supply in accordance with the instructions provided in
the wiring diagram included in the manual.
• Always verify that electric connections (cable entry,
section of leads, protections…) are compliant with the
electric specifications and with the instructions provided
in the wiring scheme. Always verify that all connections
comply with the standards applicable to the installation
of air conditioners.
• Devices disconnected from the power supply should be
completely disconnected in the condition of overvoltage
category.
• Be sure not to perform power cable modification,
extension wiring, and multiple wire connection.
It may cause electric shock or fire due to poor
connection, poor insulation, or current limit
override.
When extension wiring is required due to power line
damage, refer to "Step 4 Optional: Extending the
power cable" in the installation manual.