Handleiding
Je bekijkt pagina 23 van 44

23
Installation Procedure
English
• Method 2: Twist the wire cores together and push it
into the sleeve.
Method 1
Connection sleeve Connection sleeve
Method 2
4 Using a crimping tool, compress the two points and flip it
over and compress another two points in the same location.
• The compression dimension should be 8.0.
Compression
dimension
• After compressing it, pull both sides of the wire to
make sure it is firmly pressed.
5 mm 5 mm
Method 1 Method 2
Compress it 4 times.Compress it 4 times.
5 Apply heat to the contraction tube to contract it.
Contraction tube
Contraction tube
Method 1 Method 2
6 Wrap it with the insulation tape twice or more and
position your contraction tube in the middle of the
insulation tape.
A total of three or more layers of insulation is required.
Method 1 Method 2
35 mm40 mm
Insulation tapeInsulation tape
7 After tube contraction work is completed, wrap it with
the insulation tape to finish.
IInsulation tape
Insulation tape
Method 1 Method 2
CAUTION
• Make sure that the connection parts are not exposed
to outside.
• Be sure to use insulation tape and a contraction tube
made of approved reinforced insulating materials that
have the same level of withstand voltage with the
power cable. (Comply with the local regulations on
extensions.)
WARNING
• In case of extending the electric wire, please DO NOT
use a round-shaped Pressing socket.
– Incomplete wire connections can cause electric shock
or a fire.