Handleiding
Je bekijkt pagina 25 van 31

25
English
Extra Procedures
Using the stop valve
Opening the stop valve
1 Openthecapandturnthestopvalveanticlockwise
byusingahexagonalwrench.
2 Turnituntiltheaxisisstopped.
Tightening torque for charging port cap
(Refer to the table)
Charging Core
Spindle
Tightening torque for body cap
(Refer to the table)
R-22 : Thread of the screw - 7/16-20UNF
R-410A : Thread of the screw - 1/2-20UNF
3 Tightenthecapsecurely.
Outer Diameter
(mm)
Tightening torque
Body cap (Nꞏm)
Charging port cap
(Nꞏm)
Ø6.35 20to25
10to12
Ø9.52 20to25
Ø12.70 25to30
Ø15.88 30to35
OverØ19.05 35to40
(1Nꞏm=10kgfꞏcm)
NOTE
• Donotapplyexcessiveforcetothestopvalveand
alwaysusespecialinstruments.Otherwise,the
stoppingboxcanbedamagedandthebacksheet
canleaks.
• Ifthewatertightsheetleaks,turntheaxisback
byhalf,tightenthestoppingbox,thencheckthe
leakageagain.Ifthereisnoleakageanymore,
tightentheaxisentirely.
Closing the stop valve
1 Removethecap.
2 Turnthestopvalveclockwisebyusingahexagonal
wrench.
3 Tightentheaxisuntilthevalvereachedthesealing
point.
4 Tightenthecapsecurely.
CAUTION
• Whenyouusetheserviceport,alwaysusea
charginghose,too.
• Checktheleakageofrefrigerantgasafter
tighteningthecap.
• Mustuseaspannerandwrenchwhenyouopen/
tightenthestopvalve.