Royal Catering RCGL-65L50H handleiding
Handleiding
Je bekijkt pagina 8 van 31

MODEL BURNERS HEAT INPUT (KW)
I3+(28~30/37) I3B/P(50) I2H(20)/I2E(25)
RCGL65 2 3.0× 2 3.0× 2 3.1× 2
RCGL75 2 3.0× 2 3.0× 2 3.1× 2
RCGL110 4 3.0× 4 3.0× 4 3.1× 4
Inlet pressure (mbar) 29 50 20
Injector orice (mm) 0.9 0.78 1.3
Destination countries BE, CH, CY, CZ,
ES, FR, GB, GR, IE,
IT, PT, SI
AT, CH, DE,
FR, SK
AT, CH, CZ, DE,
DK, EE, ES, FI, FR,
GB, GR, IE, HU, IT,
LT, LV, NL,NO, PT,
RO, SE, SI, SK
This appliance shall be installed in conformity with the current regulations and used only in a well-
ventilated location. Consult the instructions before installing and using this appliance.
VI. TECHNICAL DETAILS
Sheet 1
Fault Cause Analysis Solution
Failure in ignition • There is no gas supply
or the gas pressure
does not t.
• The switch of the
appliance is damaged.
• The ignition electrode
has loosened and
shifted.
• Check the air inlet
and the gas pressure.
• Replace the switch of
the appliance.
• Adjust the position of
the ignition electrode
and make it rm.
The re goes out
immediately after
successful ignition
• The re detector has
dislocated or the lead
has dropped.
• Lack of oxygen for
combustion
• The gas pressure is
too low or the gas
supply is insufcient.
• Adjust the re
detector to allow the
ame to go red.
• Maintain good
ventilation.
• Check and replace
the gas, or turn up
the gas supply valve.
Sheet 2
MODEL QTY OF
BURNERS
PLATE SIZE
(WXD)
PRODUT SIZE
(WXDXH)
REMARK
RCGL65 2 600x400mm 650x580x350mm
RCGL75 3 750x400mm 800x580x350mm
RCGL110 4 1100x400mm 1150x580x350mm
EN EN
14 15
Bekijk gratis de handleiding van Royal Catering RCGL-65L50H, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Royal Catering |
| Model | RCGL-65L50H |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 1466 MB |







