MODEL BURNERS HEAT INPUT (KW)
I3+(28~30/37) I3B/P(50) I2H(20)/I2E(25)
RCGL65 2 3.0× 2 3.0× 2 3.1× 2
RCGL75 2 3.0× 2 3.0× 2 3.1× 2
RCGL110 4 3.0× 4 3.0× 4 3.1× 4
Inlet pressure (mbar) 29 50 20
Injector orice (mm) 0.9 0.78 1.3
Destination countries BE, CH, CY, CZ,
ES, FR, GB, GR, IE,
IT, PT, SI
AT, CH, DE,
FR, SK
AT, CH, CZ, DE,
DK, EE, ES, FI, FR,
GB, GR, IE, HU, IT,
LT, LV, NL,NO, PT,
RO, SE, SI, SK
This appliance shall be installed in conformity with the current regulations and used only in a well-
ventilated location. Consult the instructions before installing and using this appliance.
VI. TECHNICAL DETAILS
Sheet 1
Fault Cause Analysis Solution
Failure in ignition There is no gas supply
or the gas pressure
does not t.
The switch of the
appliance is damaged.
The ignition electrode
has loosened and
shifted.
Check the air inlet
and the gas pressure.
Replace the switch of
the appliance.
Adjust the position of
the ignition electrode
and make it rm.
The re goes out
immediately after
successful ignition
The re detector has
dislocated or the lead
has dropped.
Lack of oxygen for
combustion
The gas pressure is
too low or the gas
supply is insufcient.
Adjust the re
detector to allow the
ame to go red.
Maintain good
ventilation.
Check and replace
the gas, or turn up
the gas supply valve.
Sheet 2
MODEL QTY OF
BURNERS
PLATE SIZE
(WXD)
PRODUT SIZE
(WXDXH)
REMARK
RCGL65 2 600x400mm 650x580x350mm
RCGL75 3 750x400mm 800x580x350mm
RCGL110 4 1100x400mm 1150x580x350mm