Rommelsbacher CT 2002/IN handleiding

32 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 25 van 32
25
• By touching the + sensor (3) you can in-crease the
power up to level 10.
By touching the sensor (5) you can reduce the
power down to level 01.
By default the power level mode is displayed by the figures 01 to 10. By simultaneous-
ly touching the + and sensors for 3 seconds the display switches over to show the
power values instead of the power levels; this means for example that 100 is displayed
instead of 01 and 800 instead of 06, etc.. This format is valid until the user will set it
back. The selected display format remains saved also after switch-off. Only after pulling the
mains plug or a cut-off from the mains there is a reset of the control to the default format
with the figures 01 to 10.
Details on the power levels/power values:
The values indicated are reference values and apply to steel pots with 20 cm Ø.
CT 2002/IN und CT 3402/IN left side CT 3402/IN right side
level 01 100 W level 01 100 W
level 02 200 W level 02 200 W
level 03 350 W level 03 300 W
level 04 500 W level 04 400 W
level 05 650 W level 05 500 W
level 06 800 W level 06 600 W
level 07 1000 W level 07 750 W
level 08 1250 W level 08 900 W
level 09 1500 W level 09 1100 W
level 10 2000 W level 10 1400 W
NOTE: The temperature at the bottom of the cookware is checked by a sensor in the centre of
the cooking zone. The regulation will only function properly if the cookware covers this area.
The cookware should have a flat and not too thick bottom to ensure a good heat transfer. The
maximum tolerable temperature for the power level mode is 200 °C. If a higher temperature is
measured, the power output is reduced or not at all until the temperature has dropped again.
Cooking in temperature level mode
The temperature level mode is ideal for roasting, grilling or frying.
Cooking small food quantities
Induction technology with its quick and direct heat transfer may cause a short-term
overheating of small food quantities to be cooked. Thus we recommend for heating small
quantities to start with power level mode at a low power level (01 – 03), and to switch over
to the desired temperature level after a few minutes.
Cooking large food quantities
In the upper performance range of the temperature level mode the power output is
reduced. So in order to avoid long heating-up sequences, for heating bigger quantities
(> 1500 ml) we recommend to start with power level mode at a high level (09 – 10) and to
switch over to the desired temperature level after a few minutes.

Bekijk gratis de handleiding van Rommelsbacher CT 2002/IN, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkRommelsbacher
ModelCT 2002/IN
CategorieFornuis
TaalNederlands
Grootte2712 MB