RP 251 Press Tool
999-995-443.10_REV. A
12
tool and batteries in a conditioned space until
ready to use.
Storage
Remove battery from the press tool. Store
press tool, attachments and battery in case.
Avoid storing in extreme heat or cold. The
tool will not turn ON if the tool is outside the
specification range.
Store tool in a dry, secured, locked area that
is out of reach of children and
people unfamiliar with the press tool. The tool
is dangerous in the hands of untrained users.
Maintenance
Instructions
WARNING
Make sure the battery is removed from
tool before performing maintenance or
making any adjustment.
Cleaning And Lubrication
1. Wipe the tool clean daily with a clean dry
cloth.
2. Inspect the attachment mounting pin and
lubricate the pin with silicone lubricant as
needed.
3. Check return springs in attachments with
each use. Attachments should open and
close freely with only moderate finger
effort required.
Updating Firmware
For the best user experience, it is recom-
mended that firmware be kept up to date.
Check, and if needed, update your tool firm-
ware before the first use of the product and on
a regular basis thereafter. See RIDGID Link
App Connection section.
WARNING
PROBLEM POSSIBLE REASON SOLUTION
Tool will not turn
ON when trigger/run
switch is pressed.
Attachment is locked
onto fitting.
The pressed connec-
tions produced are not
complete.
Oil leaks from tool.
Motor runs but tool
will not complete a
cycle.
Tool stops during
operation.
Troubleshooting
Battery is completely discharged or
battery has failed.
Battery not properly inserted into
handle of tool.
Press connection was not successfully
completed.
Used wrong jaw for the tube size or
material.
The tool was not square to the tube.
Attachment press contour was not
aligned with the fitting contour.
Tool is in need of repair.
Seal or mechanical problems.
Oil level low.
Oil level low.
Insert fully charged battery/replace
battery.
Check to assure battery is fully
inserted.
Push pressure retract button to re-
move jaws from fitting. Inspect and
re-press fitting.
Install the correct attachment.
Redo the press connection with new
fitting and new tube. Make sure that the
tool is square to the tube.
Redo the press connection with fitting
and new tube. Make sure the attach-
ment press contour is aligned with the
fitting contour..
See Contact Information for nearest
RIDGID Authorized Independent Service
center.
See Contact Information for near-
est RIDGID Authorized Independent
Service center.
See Figure 5 for Tool Status Lights.
See RIDGID Link App Connection section for Firmware updates.