10 Shutdown
NOTICE!
Never switch of
f the equipment by pulling out
the mains plug.
Temporary shutdown
If it is planned to shut down the unit for longer
periods e.g. during the winter
, proceed as follows:
1. Let the unit run in recirculating operation for
ca. 2 hours in order to dry the surfaces of the
evaporator fins. This will transport the
remaining moisture out of the unit and this
will avoid unpleasant odours when the unit is
re-commissioned.
2. Switch the unit of
f with the "I/O" key, pull out
the power plug and wind up the power
supply. Ensure that the cable is not kinked or
too severely bent. The line can be fastened
to the rear of the unit.
3. Place a suitable container underneath the
condensate drain of the internal reservoir
.
The condensate drain is located on the lower
rear side of the unit.
4. Pull out the stopper from the condensate
drain and collect the condensate that drains
out.
5. Then insert the stopper once again. A
missing stopper or an incorrectly inserted
stopper will result in condensate leaking out
after re-commissioning.
6. Store the unit in an upright position in a cool,
dry and dust-free location protected from
direct sunlight. Cover the unit with a synthetic
cover to protect it against dust if desired.
Permanent shutdown
The entire system should only be dismantled by a
specialist firm familiar with all environmental
aspects involved. REMKO GmbH & Co. KG or your
contractual partner will be pleased to provide a list
of refrigerant specialists in your area.
Before carrying out this procedure, it is essential
that the technician is completely familiar with the
equipment and all its detail. It is recommended
good practice that all refrigerants are recovered
safely
. Prior to the task being carried out, an oil
and refrigerant sample shall be taken in case anal-
ysis is required prior to re-use of reclaimed refrig-
erant. It is essential that electrical power is avail-
able before the task is commenced.
n Become familiar with the equipment and its
operation.
n Isolate system electrically
.
n Before attempting the procedure ensure that:
mechanical handling equipment is available, if
required, for handling refrigerant cylinders; all
personal protective equipment is available and
being used correctly; the recovery process is
supervised at all times by a competent person;
recovery equipment and cylinders conform to
the appropriate standards.
n Pump down refrigerant system, if possible.
n If a vacuum is not possible, make a manifold
so that refrigerant can be removed from var-
ious parts of the system.
n Make sure that cylinder is situated on the
scales before recovery takes place.
n Start the recovery machine and operate in
accordance with manufacturer's instructions.
n Do not overfill cylinders. (No more than 80 %
volume liquid charge).
n Do not exceed the maximum working pressure
of the cylinder, even temporarily.
n When the cylinders have been filled correctly
and the process completed, make sure that the
cylinders and the equipment are removed from
site promptly and all isolation valves on the
equipment are closed off.
n Recovered refrigerant shall not be charged into
another refrigeration system unless it has been
cleaned and checked.