FLAME ADJUSTMENT – see Fig. XV
The valves are adjusted by adjusting the economy flame. To do this, you should:
• turn the knob to turn on the adjustable valve
• set the knob to position 4 (Fig. V)
• in position 4, remove the knob from the valve
• turn the adjustment screw (A) and observe the flame
The flame should be set at such a height that it does not go out in the event of a slight breeze and when quickly
switched from full flame - position 3 (Fig. V) inversely. A properly adjusted flame should have the shape of a
green-blue cone, approximately 2-4 mm high.
Place the knob on the valve.
ATTENTION!
If there are visible changes in gas pressure in the gas installation, the safety flame should
be adjusted at low pressure so that the burner does not go out during normal use.
POWER TABLE AND NOZZLE DIAMETERS DEPENDING ON THE TYPE OF SUPPLY GAS
Gas type
Burner
2E - G20 – 20 mbar
Small (5)
Middle (2; 4)
Big (3)
WOK (6)
Diameter injector [mm]
0,70
0,92
1,20
1,55
Nominal input [kW]
0,90
1,55
2,60
4,20
Gas consumption [m
3
/h]
0,086
0,148
0,248
0,400
Gas type
Burner
3B/P-G30 37mbar
Small (5)
Middle (2; 4)
Big (3)
WOK (6)
Diameter injector [mm]
0,50
0,65
0,80
1,00
Nominal input [kW]
1,10
1,70
2,60
4,20
Gas consumption [g/h]
79
124
189
305
COMMON FAULTS
1. Ignition does not ignite the gas or does not always ignite it
• Check if the appliance is connected to the electricity network
• Clean and dry the burner components and ignition
• Check that the burner caps and caps are installed correctly
2. The gas does not ignite
• Check whether the rubber hose has not been crushed when powered by liquid gas
from the cylinder
• Check that the main gas valve is open
• Check whether the gas cylinder is not empty
• If a new appliance has been installed or the gas cylinder has been replaced with a new one, the
ignition procedure must be repeated until the gas reaches the burner
• Check whether the nozzle or flame holes in the burner are not dirty or flooded. If so, clean the nozzle
hole using a pin or needle. Use a brush to clean the holes in the burner. Then dry all the elements
3. Unstable flame
• Check whether the burner components are clean, dry and correctly installed
If the above suggestions do not solve the problem, contact the service.
It is forbidden not to attempt to repair it yourself. The device may only be repaired by a qualified, authorized
person.
The applaince should only be repaired by an authorized service center using original spare parts.
Bekijk gratis de handleiding van Ravanson KWGE-90R, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Ravanson |
| Model | KWGE-90R |
| Categorie | Fornuis |
| Taal | Nederlands |
| Grootte | 13051 MB |